SDS

2
swallowed, call a physician immediately. Loosen tight
clothing such as a collar, tie, belt or waistband.
Inhalation Remove from exposure to fresh air immediately. If not
breathing, give articial respiration. If breathing is dicult,
give oxygen. Get medical aid if cough or other symptoms
appear.
Section 5: Fire-Fighting Measures
Flammability of the Product Non-ammable.
Auto-Ignition Temperature Not applicable.
Flash Points Not applicable.
Flammable Limits Not applicable.
Products of Combustion Not available.
Fire Hazards in Presence of Various Substances Not applicable.
Explosion Hazards in Presence of Various Substances
Risks of explosion of the product in presence of mechanical impact Not available.
Risks of explosion of the product in presence of static discharge Not available.
Fire Fighting Media and Instructions Not applicable.
Special Remarks on Fire Hazards Not available.
Special Remarks on Explosion Hazards Not available.
Section 6: Accidental Release Measures
Small Spill Use appropriate tools to put the spilled solid in a
convenient waste disposal container. Finish cleaning by
spreading water on the contaminated surface and
dispose of according to local and regional authority
requirements.
Large Spill Use a shovel to put the material into a convenient waste
disposal container. Finish cleaning by spreading water on
the contaminated surface and allow to evacuate through
the sanitary system.
Section 7: Handling And Storage
Precautions Do not breathe dust. Wear suitable protective clothing. In
case of insucient ventilation, wear suitable respiratory
equipment. If you feel unwell, seek medical attention and
show the label when possible. Avoid contact with skin
and eyes. Keep away from incompatibles such as metals,
acids.
Storage Hygroscopic. Keep container tightly closed. Keep
container in a cool, well-ventilated area.
Section 8: Exposure Controls/Personal Protection
Engineering Controls Use process enclosures, local exhaust ventilation, or
other engineering controls to keep airborne levels below
recommended exposure limits. If user operations
generate dust, fume or mist, use ventilation to keep
exposure to airborne contaminants below the exposure
limit.
Personal Protection Splash goggles. Lab coat. Dust respirator. Be sure to use
an approved/certied respirator or equivalent. Gloves.