Use and Care Manual

GB - 16
Ariens dealers will provide any service or
adjustments which may be required to keep
your unit operating at peak efficiency. Should
engine service be required, contact an Ariens
dealer or an authorized engine
manufacturer's service center.
SERVICE POSITION
Place unit on a flat level surface. Tip unit
forward onto front of auger housing for
service. Ensure unit is secure and will not tip
over. Strap and clamp onto bench if needed.
MAINTENANCE SCHEDULE
The chart below shows the recommended
maintenance schedule that should be
performed on a regular basis. More frequent
service may be required.
* After first five hours of operation.
** After first two hours of operation.
CHECK FASTENERS
Make sure all hardware is tightened properly.
CHECK CLUTCH OPERATION
Auger/impeller must stop within 5 seconds
when attachment clutch/impeller brake lever
is released.
Wheels must stop quickly when traction drive
clutch lever is released.
If clutches do not engage or disengage
properly, adjust or repair before operation
(see Attachment Clutch/Brake Adjustment on
page 19 or Traction Drive Clutch Adjustment
on page 21).
MAINTENANCE
WARNING: AVOID INJURY. Read
and understand the entire Safety
section before proceeding.
WARNING: Before tipping unit up
onto housing, remove fuel so no
spills will occur. Ensure unit is
secure and will not tip over during
maintenance.
Figure 10
Service Position
MAINTENANCE
SCHEDULE
Service
Performed
Each
Use
Every
5 hrs.
Every
25
hrs.
Yearly
Check
Fasteners
Check Clutch
Operation
Check Clutch
Spring
Adjustments
*•
Clean Engine
Check Engine
Oil
Change
Engine Oil
**
Check Tire
Pressure
Check Auger
Gearcase
••
General
Lubrication
••