User's Manual

Table Of Contents
Tel:0551-65538567
25
electricity meter in this field, which is the basis for anti-Anti-reflux later)
Function code- Function code, selected according to communication protocol.
Data format- Data type, selected according to communication protocol.
Byte Serial Number - serial number of the data byte, selected based on the
communication protocol.
Register address- register address, selected according to communication
protocol.
End identity- end identity, usually 0.
Fig. 6-15 Adding Point Table
All the measurement points needed should be added to the template according to
the communication protocol of the equipment.
6.5.3 Adding Equipment
Click [Equipment] - >[Equipment Measured Point] button to increase the
number of equipment to be collected and then click [+New] button to add them.
Fig. 6-16 Adding Equipment Measuring Point
Enter the name, select the equipment type, and click [Sure] button, then the