G1000 Owner’s Manual / Manual del Propietario Snapper™ is a licensed trademark of Briggs & Stratton Power Products. Snapper™ se usa abajo licencia a Briggs & Stratton Power Products. Questions? Help is just a moment away! Preguntas? La ayuda es justa un momento lejos! Call: Generator Helpline - 1-800-317-7833 M-F 8-5 CT Llamada: Generador Helpline - 1-800-317-7833 M-F 8-5 CT BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC JEFFERSON, WISCONSIN, U.S.A. Model No. 01666-0 (1000 Watt AC Generator) Manual No.
Snapper G1000 Generator TABLE OF CONTENTS SAFETY RULES Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 Know Your Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-12 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Maintenance . . . . . .
Snapper G1000 Generator WARNING WARNING Running generator gives off carbon monoxide, an odorless, colorless, poison gas. Breathing carbon monoxide will cause nausea, fainting or death. Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death. • Operate generator ONLY outdoors. WHEN ADDING OR DRAINING FUEL • Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.
Snapper G1000 Generator CAUTION WARNING Excessively high operating speeds increase risk of injury and damage to generator. Excessively low speeds impose a heavy load. Rapid retraction of starter cord (kickback) will pull hand and arm toward engine faster than you can let go. Broken bones, fractures, bruises or sprains could result. • DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed. • DO NOT modify generator in any way.
Snapper G1000 Generator KNOW YOUR GENERATOR Read this owner’s manual and safety rules before operating your generator. Compare the illustrations with your generator to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. Spark Plug (inside cover) Fuel Tank Engine ON/OFF Switch 12 Volt DC, 8.3 Amp Accessory Jack Choke Lever Circuit Breaker (AC) Air Cleaner 120 Volt AC, 7.
Snapper G1000 Generator ASSEMBLY BEFORE STARTING ENGINE Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended oil and fuel. Add Engine Oil and Fuel • Place generator on a level surface. CAUTION If you have any problems with the assembly of your generator, please call the generator helpline at 1-800-317-7833. If calling for assistance, please have the model, revision, and serial number from the data tag available.
Snapper G1000 Generator USING THE GENERATOR Generator Location Generator Clearance System Ground WARNING The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles. The system ground is not connected to the AC neutral wire. If the generator is tested by a receptacle tester, it will not show the same ground circuit condition as for a home receptacle. Running generator gives off carbon monoxide, an odorless, colorless, poison gas.
Snapper G1000 Generator OPERATING THE GENERATOR WARNING Rapid retraction of starter cord (kickback) will pull hand and arm toward engine faster than you can let go. Broken bones, fractures, bruises or sprains could result. CAUTION Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it. • When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.
Snapper G1000 Generator Stopping the Engine 1. Turn OFF and unplug all electrical loads from generator panel receptacles. NEVER start or stop engine with electrical devices plugged in and turned ON. 2. Let engine run at no-load for several minutes to stabilize internal temperatures of engine and generator. 3. Turn engine off according to instructions given in the engine owner’s manual. 4. Move fuel valve to “Off” position. 3.
Snapper G1000 Generator CONNECTOR PLUGS This receptacle can not recharge 6 Volt batteries and can not be used to crank an engine having a discharged battery. See “Charging a Battery” (page 9) before attempting to recharge a battery. CAUTION Receptacles may be marked with rating value greater than generator output capacity. EXTENSION CORDS • NEVER attempt to power a device requiring more amperage than generator or receptacle can supply. • DO NOT overload the generator. See “Don’t Overload Generator”.
Snapper G1000 Generator In an emergency, use the original shipping carton as a temporary shelter: For a more permanent shelter, build a structure that will enclose three sides and the top of the generator. 7. Cut off all carton flaps. 7. 8. Cut out one long side of carton to expose muffler side of unit as shown in Figure 6. Make sure entire muffler-side of generator is exposed, as shown in Figure 6. IMPORTANT: The generator must be at least 5 ft.
Snapper G1000 Generator DON'T OVERLOAD GENERATOR 4. Plug in and turn on the next load. 5. Again, permit the generator to stabilize. 6. Repeat steps 4 and 5 for each additional load. NEVER add more loads than the generator capacity. Take special care to consider surge loads in generator capacity, as described above. Capacity You must make sure your generator can supply enough rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps: 1.
Snapper G1000 Generator SPECIFICATIONS Generator Maintenance Rated Surge Watts . . . . . . . . . . . . . . . . . . . . . . . . 1,000 Watts Rated Running Watts . . . . . . . . . . . . . . . . . . . . . . . . 900 Watts Rated Maximum Current At 120 Volts AC . . . . . . . . . . . . . . . . . . . . . . . . . .7.5 Amps At 12 Volts DC . . . . . . . . . . . . . . . . . . . . . . . . . . .8.3 Amps Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Single Phase Rated Frequency . . . . . .
Snapper G1000 Generator STORAGE Engine Storage See engine owner’s manual for instructions. The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage. Other Storage Tips • To prevent gum from forming in fuel system or on essential carburetor parts, add fuel stabilizer into fuel tank and fill with fresh fuel.
Snapper G1000 Generator TROUBLESHOOTING Problem No AC output is available, but generator is running. Generator runs good at no-load but "bogs" down" when loads are connected. Cause Correction 1. One of the circuit breakers is open. 1. Reset circuit breaker. 2. Fault in generator. 2. Contact Authorized service facility. 3. Poor connection or defective cord 3. set. Check and repair. 4. Connected device is bad. 4. Connect another device that is in good condition. 1.
Snapper G1000 Generator NOTES 16
SNAPPER™ OWNER WARRANTY POLICY Effective August 1, 2004 LIMITED WARRANTY “Snapper™ is a licensed trademark of Briggs & Stratton Power Products. Briggs & Stratton Power Products will repair or replace, free of charge, any part, or parts of the equipment** that are defective in material or workmanship or both. Transportation charges on parts submitted for repair or replacement under this warranty must be borne by purchaser.
Snapper G1000 Generador TABLA DE CONTENIDOS INSTRUCCIONES DE SEGURIDAD Reglas De Seguridad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-20 Conozca Su Generador . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Ensamblaje. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Funcionamiento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23-28 Mantenimiento . . . . . . . . . . . . . . . . . . . . . . . . . . .
Snapper G1000 Generador ADVERTENCIA ADVERTENCIA Al generador funcionar, se produce monóxido de carbono, un gas inodoro y venenoso. El respirar el monóxido de carbono, producirá náusea, desmayo o la muerte. La combustible y sus vapores son extremadamente inflamables y explosivos. El fuego o una explosión pueden causar quemaduras severas e inclusive la muerte. • Opere el generador SOLAMENTE al aire libre.
Snapper G1000 Generador ADVERTENCIA PRECAUCIÓN Las velocidades de operación en exceso, aumentan los riesgos de heridas y daños al generador. Las velocidades bajan en exceso, imponen una carga muy pesada. El rápido repliegue del cable del arrancador (retroceso) impedirá que el usuario suelte el cable a tiempo y tirará de su mano y brazo hacia el motor. Como resultado, podrían producirse fracturas, contusiones o esguinces. • NO cambie ninguna velocidad determinada.
Snapper G1000 Generador CONOZCA SU GENERADOR Lea este manual del propietario y las reglas de seguridad antes de operar su generador. Compare las ilustraciones con su generador para familiarizarse con la ubicación de los diferentes controles y ajustes. Conserve este manual para referencias futuras. Bujía (cubierta del interior) Tanque de Combustible Interruptor de Encendido Clavija Accesoria de 12 Voltios DC, 8.
Snapper G1000 Generador MONTAJE ANTES DE DARLE ARRANQUE AL MOTOR Su generador requiere de ciertos procedimientos de montaje y solo estará listo para ser utilizado después de haberle suministrado servicio con el combustible y aceite recomendados. Agregar Aceite al Motor y Gasolina Si usted tiene problemas con el montaje de su generador, por favor llame a la línea de ayuda para generadores al 1-800-317-7833.
Snapper G1000 Generador USO DEL GENERADOR Ubicación del Generador Espacio Libre Alrededor del Generador Tierra del Sistema ADVERTENCIA El generador dispone de una conexión a tierra del sistema que conecta los componentes del bastidor a los terminales de tierra de los enchufes hembra de salida de CA. La tierra del sistema no está conectada al cable de CA neutro.
Snapper G1000 Generador OPERANDO EL GENERADOR PRECAUCIÓN ADVERTENCIA El rápido repliegue del cable del arrancador (retroceso) impedirá que el usuario suelte el cable a tiempo y tirará de su mano y brazo hacia el motor. Como resultado, podrían producirse fracturas, contusiones o esguinces. El sobrepasar la capacidad del amperaje y vataje del generador, puede dañar al generador y los aparatos eléctricos conectados al mismo. • Vea "No sobrecargue generador".
Snapper G1000 Generador Parado Del Motor 1. 2. 3. 4. Gire lejos y desconecte todas las cargas eléctricas de los tomaco-rrientes del panel del generador. NUNCA de arranque o detenga el motor con todos los dispositivos eléctricos conectados y encendidos. 3. Si la batería está equipada con tapas de desfogue, asegúrese de que están instaladas y apretadas. 4. Conecte el enchufe conector del cable de carga de la batería al tomacorrientes del panel. 5.
Snapper G1000 Generador ENCHUFES DE CONEXIÓN PRECAUCIÓN Este receptáculo no puede recargar las baterías de 6 Voltios y no puede ser utilizado tampoco para arrancar un motor que tenga la batería descargada. Consulte “Cargando una Batería” (página 25) antes de intentar recargar cualquier batería. El valor nominal que se indica en los enchufes hembra puede ser superior a la capacidad de salida del generador.
Snapper G1000 Generador Para una protección más permanente, construya una estructura que rodee los tres lados y la parte superior del generador. 7. Asegúrese de que quede expuesto el lado completo del silenciador del generador, como se muestra en la Figura 13. En caso de emergencia, utilice la caja de cartón del embalaje original como una protección temporal. 7. Corte las tapas de la caja. 8.
Snapper G1000 Generador NO SOBRECARGUE EL GENERADOR 4. 5. 6. Conecte y encienda la próxima carga. De nuevo, permita que el generador se estabilice. Repita los pasos 4 y 5 para cada carga adicional que usted tenga. NUNCA añada más cargas sobre la capacidad del generador. Tome una atención especial en considerar las cargas de corriente según la capacidad del generador, como se describe arriba.
Snapper G1000 Generador NOTA: NO recomendamos el uso de mangueras de jardín para limpiar el generador. El agua podría introducirse en el sistema de combustible del motor y causar problemas. Además, si el agua se introduce al generador a través de las ranuras para aire de enfriamiento, algo del agua quedará retenida en los espacios vacíos y grietas del aislamiento del devanado del estator y rotor.
Snapper G1000 Generador ALMACENAMIENTO Almacenando el Motor El generador deberá ser encendido al menos una vez cada siete días y deberá dejarlo funcionar al menos durante 30 minutos. Si no puede hacer esto y debe almacenar la unidad por más de 30 días, siga las siguientes instrucciones para preparar su unidad para almacenamiento. Consulte el manual del propietario del motor para las instrucciones de cómo preparar adecuadamente el motor para su almacenamiento.
Snapper G1000 Generador DIAGNÓSTICO Y REPARACIÓN DE AVERÍAS Problemo El motor está funcionando pero no existe salida de AC disponsible. Accion Causa 1. El interruptor automático de circuito está abierto. 1. Reposicione el interruptor. 2. Conexión mal o defectuosa del juego de cables. 2. Revise y repare. 3. El dispositivo conectado está dañado. 3. Conecte otro dispositivo que esté buenas condiciones. 4. Avería en el generador. 4. Contacte el distribuidor de servicio autorizado. 1.
POLÍTICA PARA EL PROPIETARIO DE EQUIPOS SNAPPER™ Efectiva desde el 1 ro de Agosto, 2004 GARANTÍA LIMITADA "Snapper™ se usa abajo licencia a Briggs & Stratton Power Products. Briggs & Stratton Power Products reparará o sustituirá sin cargo alguno cualquier componente del equipo** que presente defectos de materiales y/o mano de obra. Los gastos de transporte de las piezas enviadas para reparar o sustituir conforme a los términos de esta garantía correrán a cargo del comprador.