G1000 Portable Generator Owner’s Manual Model No. 1666-0 (1,000 Watt AC Generator) Manual No.
Snapper G1000 Generator TABLE OF CONTENTS or serious injury. WARNING indicates a hazard which, if not avoided, could result in death or serious injury. CAUTION indicates a hazard which, if not avoided, might result in minor or moderate injury. CAUTION, when used without the alert symbol, indicates a situation that could result in equipment damage. Follow safety messages to avoid or reduce the risk of injury or death. Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Snapper G1000 Generator WARNING WARNING Running engines produce heat. Temperature of muffler and nearby areas can reach or exceed 150°F (65°C). Severe burns can occur on contact. Generator produces powerful voltage. Failure to properly ground generator can result in electrocution. Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy. • Do not touch hot surfaces. • Allow equipment to cool before touching.
Snapper G1000 Generator KNOW YOUR GENERATOR Read this owner’s manual and safety rules before operating your generator. Compare the illustrations with your generator to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. Spark Plug (inside cover) Fuel Tank Engine ON/OFF Switch 12 Volt DC, 8.3 Amp Accessory Jack Choke Lever Circuit Breaker (AC) Air Cleaner 120 Volt AC, 7.
Snapper G1000 Generator CONTENTS • If the oil level is not at the point of overflowing from the oil filler neck, slowly fill engine with recommended oil. Check all contents. If any parts are missing or damaged, call the generator helpline at 1-800-270-1408. Shipped with your generator is: • Reinstall oil filler cap and tighten securely. • Replace the oil fill cover. • Check the engine oil level before starting each time thereafter.
Snapper G1000 Generator GROUNDING THE GENERATOR • Be sure the spark plug wire is attached to the spark plug. • Turn the fuel valve to the “Open” position (fully clockwise) (Figure 4). Figure 4 — Fuel Valve in Open Position The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground. Local electrical codes may also require proper grounding of the unit.
Snapper G1000 Generator Oil Alert System • Grasp starter grip and slowly pull the rope until you feel some resistance, then pull the cord out with a rapid full arm stroke. Let rope return slowly. Do Not let rope “snap back” against the unit. The Oil Alert System is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase.
Snapper G1000 Generator CAUTION! Although each receptacle is rated Figure 7 — Battery Connections for 120 Volts at 15 Amps (1,440 watts or 1.44 kW), the generator is rated for a total of 1,000 watts. Powering loads that exceed the wattage capacity of the generator can damage it or cause serious injuries. The total of loads powered through these receptacles should not exceed 7.5 Amps.
Snapper G1000 Generator DON'T OVERLOAD YOUR GENERATOR 4. Plug in and turn on the next load. 5. Again, permit the generator to stabilize. 6. Repeat steps 4 and 5 for each additional load. Never add more loads than the generator capacity. Take special care to consider surge loads in generator capacity, as described above. Capacity You must make sure your generator can supply enough rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps: 1.
Snapper G1000 Generator PRODUCT SPECIFICATIONS GENERAL MAINTENANCE RECOMMENDATIONS The generator warranty does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, operator must maintain generator as instructed in this manual. Generator Specifications Rated Surge Watts . . . . . . . . . . . . . . . 1,000 Watts Rated Running Watts . . . . . . . . . . . . . 900 Watts Rated Maximum Current At 120 Volts AC . . . . . . . . . . . . . .7.
Snapper G1000 Generator Check the cleanliness of the generator frequently and clean when dust, dirt, oil, moisture or other foreign substances are visible on its exterior surface. • Remove the oil fill cover and clean area around oil drain plug (Figure 12). Figure 12 — Oil Drain Plug NOTE: Do Not use a garden hose to clean generator. Water can enter engine fuel system and cause problems.
Snapper G1000 Generator Figure 13 — Service Spark Plug Figure 14 – Service Spark Arrester Screen Muffler Spark Arrester Screen • Reinstall spark plug. Spark Arrester Attachment Screw Service Air Cleaner Your engine will not run properly and may be damaged if you run it using a dirty air filter element. Check the air filter every use and clean or replace the air filter element every 50 hours of operation or every three months, whichever comes first.
Snapper G1000 Generator Long Term Storage Instructions • Retighten drain screw before refueling. Change Oil While engine is still warm, change oil as described on page 11. Refill with recommended grade. WARNING! Never store engine with fuel in tank indoors or in enclosed, poorly ventilated areas where fumes may reach an open flame, spark or pilot light as on a furnace, water heater, clothes dryer or other gas appliance. Be sure the storage area is free from excessive humidity and dust.
Snapper G1000 Generator TROUBLESHOOTING Problem Cause Correction Engine is running, but no AC or DC output is available. 1. 2. 3. 4. One of the circuit breakers is open. Fault in generator. Poor connection or defective cord set. Connected device is bad. 1. 2. 3. 4. 1. 2. 3. Short circuit in a connected load. Engine speed is too slow. Generator is overloaded. 1. 2. 3. 4. 1. 2. 3. 4. Shorted generator circuit. Engine switch set to “Off”. Dirty air cleaner. Out of gasoline. Stale gasoline. 4. 1.
Snapper G1000 Generator WIRING DIAGRAM 15
Snapper G1000 Generator EXPLODED VIEW AND PARTS LIST – MAIN UNIT Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Part # NSP 187378GS 187411GS 187379GS 187430GS 187409GS 187381GS 187399GS 187382GS 187388GS 187389GS 187405GS 187384GS 187407GS 187403GS Qty 1 1 1 1 1 1 1 3 1 1 3 1 1 1 1 Description ENG, MITSUB, 2.
Snapper G1000 Generator EXPLODED VIEW AND PARTS LIST – MAIN UNIT Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Part # 187436GS 187439GS 187438GS 187769GS 187437GS 187766GS 187756GS 187875GS 190200GS 187772GS 187757GS 187760GS 187435GS 187775GS 187768GS 187774GS 187761GS 187463GS 187874GS NSP 187457GS 187765GS 187759GS Qty 1 1 1 3 1 1 4 1 1 1 5 11 1 3 1 4 8 1 1 1 1 1 2 Description CAP, FUEL PACKING, TANK FLTR, FUEL U-PACKING TANK, FUEL, 4.
Snapper G1000 Generator EXPLODED VIEW AND PARTS LIST – ENGINE Cylinder Block, Cylinder Head Item 1 2 3 4 5 6 7 8 9 Item 1 2 3 4 5 6 7 8 9 10 Part # 187404GS 187406GS 187408GS 187410GS 187412GS 187414GS 187416GS 187417GS 187418GS 187421GS Qty 1 2 2 2 2 2 1 2 2 1 Description ASSY, CYL HEAD TPPT, CYL HEAD VLV, EXH SPRNG, VLV RTNR, VLV SPG ROD, PUSH ASSY, RCKR, ARM NUT, CYL HEAD SCRW, ADJST PLT, CYL HEAD Item 11 12 13 14 15 16 17 18 19 18 Part # 187380GS 187386GS 187387GS 187391GS 187393GS 187394GS 1873
Snapper G1000 Generator EXPLODED VIEW AND PARTS LIST – ENGINE Crankcase Cover, Crankshaft/Camshaft Item 1 2 3 4 5 6 7 8 Part # 187394GS 187473GS 187474GS 187475GS 187477GS 187478GS 187428GS 187479GS Item 1 2 3 4 6 7 8 19 Part # 187481GS 187484GS 187486GS 187487GS 187488GS 187489GS 187490GS Qty 2 1 1 1 1 6 2 1 Description SEAL, OIL CVR, CRANKCASE DIPSTICK, OIL O-RING, DIPSTICK BRG, PTO BOLT, CRANKCASE CVR PIN, DWL GSKT, CRANKCASE CVR Qty 1 1 2 1 1 1 1 Description ASSY, CRNKSHFT GEAR, CRNKSHFT KEY, W
Snapper G1000 Generator EXPLODED VIEW AND PARTS LIST – ENGINE Piston/Rod, Magneto/Flywheel, Air Cleaner Item 1 1 1 2 3 3 3 4 5 5 5 6 20 Part # 187526GS 187527GS 187528GS 187529GS 187530GS 187531GS 187532GS 187533GS 187534GS 187535GS 187537GS 187539GS Qty 1 1 1 2 1 1 1 1 1 1 1 2 Description ROD, CNNCTNG, STD ROD, CNNCTNG, US.25 ROD, CNNCTNG, US.50 BOLT, CNNCTNG ROD ASSY, PSTN, STD ASSY, PSTN, OS.25 ASSY, PSTN, OS.50 PIN, PISTON SET, RING, PSTN, STD SET, RING, PSTN, OS.25 SET, RING, PSTN, OS.
Snapper G1000 Generator EXPLODED VIEW AND PARTS LIST – ENGINE Carburetor, Control/Linkages Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 21 Part # 187469GS 187471GS 187476GS 187480GS 187482GS 187483GS 187485GS 187491GS 187493GS 187495GS 187499GS 187502GS 187509GS 187511GS 187525GS 187536GS 187538GS 187542GS 187502GS 187547GS 187548GS 187549GS 187550GS 187551GS 187552GS 187553GS 187554GS 187556GS 187504GS Part # 187505GS 1875
Snapper G1000 Generator EXPLODED VIEW AND PARTS LIST – ENGINE Fan Cover, Recoil Starter, Oil Sensor Item 1 2 3 4 Part # 187521GS 187522GS 187523GS 187524GS Qty 1 1 1 4 Description CVR, FAN CVR, FAN CVR, FAN BOLT, FAN CVR Item 1 2 3 4 5 6 Part # 187557GS 187558GS 187559GS 187560GS 187561GS 187562GS Qty 1 1 1 1 1 3 Description ASSY, RECOIL, STRTR STRTR, RECOIL ROPE, RECOIL HNDL, RECOIL PULLEY, STRTR BOLT, FLNG Item 1 2 3 4 5 6 7 8 22 Part # 187563GS 187564GS 187565GS 187566GS 187567GS 187470GS 187
Snapper G1000 Generator EXPLODED VIEW AND PARTS LIST – ENGINE Lead Wires, Muffler, Gasket Set Item 1 2 3 4 5 Part # 187571GS 187572GS 187573GS 187574GS 187575GS Qty 1 1 1 1 1 Description WIRE, LEAD PLUG, SPARK CAP, PLUG TIEWRAP, LEAD WIRE WIRE, LEAD Item 1 2 3 4 5 6 7 8 Part # 187449GS 188261GS 187446GS 187455GS 187451GS 187444GS 188263GS 188262GS Qty 3 1 1 2 1 1 1 1 Description NUT, FLNG PIPE, TAIL GSKT, MFFLR NUT, CONICAL GSKT, MFFLR MFFLR SCREEN, SPARK SCREW Item 1 2 3 4 5 6 23 Part # 187461G
Snapper G1000 Generador TABLA DE CONTENIDOS el cual, si no se evita, causará la muerte o una herida grave. ADVERTENCIA indica un riesgo el cual, si no se evita, puede causar la muerte o una herida grave. PRECAUCIÓN indica un riesgo, el cual, si no se evita, puede causar heridas menores o moderadas. PRECAUCIÓN, cuando se usa sin el símbolo de alerta, indica una situación que podría resultar en el daño del equipo.
Snapper G1000 Generador ADVERTENCIA ADVERTENCIA Los motores al funcionar producen calor. La temperatura del silenciador y de las áreas cercanas puede alcanzar o pasar los 150°F (65°C). Quemaduras severas pueden ocurrir al hacer contacto. Los generadores producen un voltaje muy poderoso. Si no hace tierra apropiadamente con un generador, puede hacer que ocurra un electrocutamiento.
Snapper G1000 Generador CONOZCA SU GENERADOR Lea este manual del propietario y las reglas de seguridad antes de operar su generador. Compare las ilustraciones con su generador para familiarizarse con la ubicación de los diferentes controles y ajustes. Conserve este manual para referencias futuras. Bujía (cubierta del interior) Tanque de Combustible Interruptor de Encendido Clavija Accesoria de 12 Voltios DC, 8.
Snapper G1000 Generador CONTENIDO DEL EMPAQUE Si cualquiera de las partes no están presente o se encuentran dañadas, llame a la línea de ayuda del generador al 1-800-270-1408. Verifique el contenido contra la lista de artículos detallados a continuación: • Unidad principal • Manual del propietario • Cable para recargar la batería • Si el nivel de aceite no se encuentra en el punto de desbordamiento del cuello del rellenador de aceite, llene lentamente el motor con el aceite recomendado.
Snapper G1000 Generador CONEXION A TIERRA DEL GENERADOR • El Código Eléctrico Nacional exige que el bastidor y las partes externas conductoras de electricidad del generador se encuentren conectadas adecuadamente a una tierra física aprobada. Los códigos eléctricos locales también podrían exigir la conexión a tierra de la unidad. Para tal propósito, se ha suministrado una tuerca mariposa para conexión a tierra en la base del armazón (Figura 18).
Snapper G1000 Generador ¡PRECAUCIÓN! ¡Peligro al respirar! Nunca haga ¡ADVERTENCIA! No permita que se fume, llamas abiertas, chispas o cualquier otra fuente de calor alrededor de la batería. No utilice un encendedor o cualquier clase de llama para revisar los niveles del líquido de la batería. Use anteojos de protección, delantal de caucho y guantes de caucho cuando trabaje alrededor de la batería.
Snapper G1000 Generador • Clavija Accesoria de 12 Voltios DC, 8.3 Amperios Arranque el motor. Deje que el motor funcione mientras la batería se recarga. • Cuando la batería haya cargado, apague el motor (vea “Parado del Motor” a continuación). NOTA: Use un hidrómetro para automóviles para probar el estado de carga y condición de la batería. Siga cuidadosamente las instrucciones del fabricante del hidrómetro.
Snapper G1000 Generador NO SOBRECARGUE EL GENERADOR 4. 5. 6. Conecte y encienda la próxima carga. De nuevo, permita que el generador se estabilice. Repita los pasos 4 y 5 para cada carga adicional que usted tenga. Nunca añada más cargas sobre la capacidad del generador. Tome una atención especial en considerar las cargas de corriente según la capacidad del generador, como se describe arriba.
Snapper G1000 Generador ESPECIFICACIONES DEL PRODUCTO RECOMENDACIONES MANTENIMIENTO GENERALES Especificaciones del Generador La garantía del generador no cubre aquellas partes que hayan sido sujetas al abuso o a la negligencia del operario. Para recibir la cobertura completa de la garantía, el operario deberá mantener al generador conforme se describe en el presente manual. Wattaje de Funcionamiento . . . . . . . 900 Watts (0.9 kW) Wattaje de Variación . . . . . . . . . . . . 1,000 Watts (1.
Snapper G1000 Generador NOTA: No utilice una manguera de jardín para limpiar el generador. El agua puede entrar al sistema de combustible del motor y ocasionar problemas severos. Además, si el agua ingresa al generador a través de las ventilas, alguna porción de agua podría permanecer en los huecos o grietas del rotor y del aislamiento que envuelve al estator.
Snapper G1000 Generador • Verifique el espacio de la bujía con un calibrador y colóquelo, si es necesario,a una distancia de entre 0.028 y 0.031 pulgadas (0.7 a 0.8 mm) (Figura 28). Revise el tamiz protector contra chispas y tenga el centro del servicio reemplácelo si está doblado, perforado o dañado en cualquier otra forma. No utilice un tamiz defectuoso. Si el tamiz no está dañado, cepíllelo con un cepillo de cerdas rígidas de metal.
Snapper G1000 Generador Un Mes a Un Año Cambie el Aceite Drene el flotador del carburador (consulte la sección “Proteja el Sistema de Combustible”) y el tanque de combustible en un contenedor apropiado. Después de sacarlo del almacenamiento, llénelo con gasolina nueva antes de arrancarlo. Mientras el motor está todavía caliente, drene el aceite del contenedor del motor. Rellene con aceite de la gradación recomendada.
Snapper G1000 Generator DIAGNÓSTICO Y REPARACIÓN DE AVERÍAS Problema El motor está funcionando pero no existe salida de AC disponible. El motor funciona bien sin cargas pero “funciona mal” cuando las cargas son conectadas. El motor no arranca; o arranca y funciona mal. Causa Solución 1. 2. Uno de los cotacircuitos está abierto. Falla en el generador. 1. 2. 3. 3. 4. Mala conexión o juego de cordones defectuoso. El dispositivo conectado está en mal estado. 1. 2.
EMISSION CONTROL SYSTEM WARRANTY Your Warranty Rights and Obligations • If you have any questions regarding your warranty rights and responsibilities, your should contact your nearest authorized service center. The California Air Resources Board ("CARB") and Generac Portable Products, are pleased to explain the Emission Control System Warranty on your model year 2000 and later small offroad engine (engine).
GARANTIA DEL SISTEMA DE CONTROL DE EMISIONES Sus Obligaciones y Derechos de Garantía • La Junta Directiva de Recursos Ambientales de California (“CARB”) y Snapper, tienen el gusto de explicar la Garantía del Sistema de Control de Emisiones de su motor (motor) pequeño año 2000 y modelos posteriores. En California, los motores nuevos deben ser diseñados, fabricados y equipados para cumplir con los estrictos estándares anti-polución del Estado.
GARANTÍA LIMITADA PÓLIZA DE GARANTÍA PARA LOS PROPIETARIOS DE SNAPPER™ Efectiva desde el 1ro de Octubre, 2001 GARANTÍA LIMITADA "Esto más Snapper™ producto es distribuido abajo licencia por Generac Portable Products, LLC, una sucursal de Briggs & Stratton. Los productos portátiles Generac, LLC reparará o reemplazará, sin costo alguno, cualquier parte o partes del equipo que estén defectuosas en materiales o mano de obra, o ambos.
LIMITED WARRANTY SNAPPER® OWNER WARRANTY POLICY Effective October 1, 2001 LIMITED WARRANTY “This Snapper™ product is distributed under license by Generac Portable Products, LLC, a subsidiary of Briggs & Stratton. Generac Portable Products LLC will repair or replace, free of charge, any part, or parts of the equipment that are defective in material or workmanship or both. Transportation charges on parts submitted for repair or replacement under this Warranty must be borne by purchaser.