Instructions / Assembly

7
BATTERY REPLACEMENT
Replacement Battery Specs: 12v, 12 amp/
hr lead acid sealed, AGM type. Universal
Battery model no UB12120 or equivalent.
Two (2) Batteries required.
1. Remove the batter pack from the cart.
2. Remove the four (4) #10 screws holding
the lid in place.
3. Carefully remove the batteries, and
disconnect the spade terminals. RECYCLE
YOUR OLD BATTERIES.
4. Reconnect the battery and circuit
breaker wires to the new batteries as shown.
It is helpful to make the
connections with the batteries outside
the box rst. The batteries are wired in
SERIES, not PARALLEL.
5. Place Battery A into the box rst,
then Battery B making sure the wires are
nested inbetween. The t is
designed to be tight.
6. Replace the box lid and secure with
four (4) #10 screws.
A
B
A
B