- Standard Microsystems User Manual Environmental Monitoring Device EVB-EMC2101

EVB-EMC2101 User Manual
SMSC EMC2101 Revision 1.5 (12-13-06)
11
NOTE: Only one jumper is to be installed on JP11 and a minimum of one jumper must be installed
for the device to operate.
3.10 Other Sensor Features
Other features such as Ideality Factor Configuration, Conversion Rate, Digital Filtering, Look-up Table
Functionality, and Standby Mode can be controlled with EMC2101 registers. See the datasheet register
description for details.
Table 3.6 ALERT
Pull-up Resistors - SMBus/FAN MODE
JUMPER NAME OPEN SHORT
JP11 33k NA Auto load via EEPROM -
Initial FAN 0% Duty Cycle
18k NA Auto load via EEPROM -
Initial FAN 100% Duty Cycle
10k NA Host load via SMBus -
initial FAN 0% Duty Cycle
5.6k NA Host load via SMBus -
initial FAN 100% Duty Cycle