User Manual

PROPRIETARY
The information contained in this document may be subject to change without notice.
The information contained in this document shall remain the sole exclusive property of s.m.s smart microwave sensors GmbH.
2012-06-07_UserManual_EKTSDG.doc I Page 10 of 15 I June 7, 2012 www.smartmicro.de
5.2 Configuring EKTSDG
EKTSDG starts up with a “default preset”. This is one of three configurable presets.
All presets can be configured by means of the EKTSDG-Remote software or with a
terminal software.
Default preset can also be selected manually directly with the EKTSDG.
See section 4.2.4.
5.2.1 Storing Settings as Presets
1. Select the desired parameters in the Live Setting section with controls (1) to (6)
2. Copy these parameters to the desired preset with selector (7)
3. Save presets with control (10)
5.2.2 Set Signal Duration
The EKTSDG sends a Doppler signal, until signal duration has elapsed and then
switches off.
1. For each preset, you may select an individual duration with control (9).
Value range is 0.1 to 60sec. Value 0 means 'unlimited'
2. Save presets with control (10)
5.2.3 Set Default Preset
Default preset will be active after normal power on of the EKTSDG. It may later be
altered directly at the EKTSDG.
1. Select default preset with (8)
2. Save presets with control (10)
5.3 Getting Help
Get help by selectig Menu-Help.
Get tips by moving cursor over the controls.