Operator's Manual

18
General Description
General Description
For more information about installing the CADD®-Solis Communication Module, see the documentation
provided with the module. For configuration of the wireless network settings of the pump and
communication module see operators manual for the Network Setup Utility software.
Pump Key
The pump key is used to securely lock a cassette or administration set to the pump. It can also
be used to lock and unlock the keypad, if allowed by the protocol setting.
Cassette, Extension Set, Administration Set
The cassette is the part of the CADD™ medication cassette reservoir or CADD
®
administration set that
attaches to the bottom of the pump. The following single-use products are compatible with the pump:
CADD™ medication cassette reservoir with a CADD
®
extension set
CADD
®
administration set
CADD
®
high volume administration set (with pump model 2110 only)
WARNING:
Follow the instructions for use provided with the CADD
medication cassette reservoir, CADD
®
extension
set, or CADD
®
administration set, paying particular attention to all warnings and cautions associated with
their use. Incorrect preparation and/or use of these products could result in serious patient injury or death.
Carefully route tubing, cords, and cables to reduce the possibility of patient entanglement or
strangulation. Failure to observe this warning could result in patient injury or death.
Note:
A CADD
®
set with free-flow protection must be used in order to prevent free-flow.
The maximum delivery rate is 500 mL/hr, however, programmed delivery rates exceeding 250 mL/hr
require the use of a high volume administration set. Do not manually adjust the delivery rate to override
pump programming without written authorization from the prescribing physician.
Smiths Medical recommends that the appropriate supplies needed to replace the cassettes are available
in case of a damaged cassette.
For detailed instructions and warnings pertaining to the CADD™ medication cassette reservoir or CADD
®
administration set, refer to the instructions for use supplied with the product for preparing the product
for use.
Remote Dose Cord
The remote dose cord can be attached to the pump and provided to the patient as an alternative
to pushing the PCA (PCEA) dose @ key to request a PCA dose. The LED on the remote dose
cord indicates PCA dose status:
Off: A PCA dose is not available.
Flashing: A PCA dose is available.
On: A PCA dose has been requested and delivery has started.
Polemount Bracket
The polemount bracket is used along with the polemount bracket adapter to attach the pump
to an IV pole.
Polemount Bracket Adapter
The polemount bracket adapter attaches to the back of the pump so that it can be mounted
on an IV pole or in a LockBox. (When a CADD Solis Communication Module is installed, a
polemount adapter is integrated with the mounting bracket of the communication module.)