User Guide
Page 6
Nozzle Maintenance
1. If nozzle clogs, remove and disassemble the nozzle assembly.
2. Clean the openings of any obstructions and reassemble.
MAINTENANCE CONTINUED
3. Inspect o-ring. If worn or damaged, remove and replace. Lubricate o-ring with petroleum jelly.
(See Figure 4)
4. Inspect check valve in bottom of barrel. If worn or damaged, remove and replace by pressing into
hole in bottom of barrel. (See Figure 5)
5. Re-install the barrel into the cap. While holding the cap securely, turn the barrel clockwise to lock the
tabs in place.
Figure 5
“R” Style
1. Inspect gasket. If worn or damaged, remove and replace. (See Figure 6)
2. To remove pump cap from pump barrel, squeeze the tabs on the cap and pull away from barrel.
(See Figure 7)
3. Inspect o-ring. If worn or damaged, remove and replace. Lubricate o-ring with petroleum jelly.
(See Figure 8)
4. Inspect check valve in bottom of barrel. If worn or damaged, remove and replace by pressing into
hole in bottom of barrel. (See Figure 9)
5. Insert the pump handle assembly into the barrel. Align the tabs of the pump cap with the rectangle
cutouts on the barrel. Push cap into place until the cap snaps securely into position. (See Figure 10)
Figure 4
Figure 7
Figure 6
Figure 8
Figure 9
Figure 10