Instruction manual
Installation
42
The appliance can work in the following
modes:
• 220-240 V 1N~
3 x 6 mm² three-core cable.
• 380-415 V 2N~
4 x 6 mm² four-core cable.
• 220-240 V 2~
3 x 6 mm² three-core cable.
• 220-240 V 3~
4 x 6 mm² four-core cable.
• 380-415 V 3N~
5 x 2.5 mm² five-core cable.
Fixed connection
Fit the power line with an all-pole circuit
breaker with a contact separation distance
sufficient to provide complete disconnection
in category III overvoltage conditions,
pursuant to installation regulations.
5.3 Instructions for the installer
• The plug must be accessible after
installation. Do not bend or trap the
power cable.
• The appliance must be installed
according to the installation diagrams.
• If the appliance does not work correctly
after having carried out all the checks,
contact your local Authorised Service
Centre.
• Once the appliance has been installed,
please explain to the user how to use it
correctly.
The values indicated above refer
to the cross-section of the internal
lead.
The aforementioned power cables
are sized taking into account the
coincidence factor (in compliance
with standard EN 60335-2-6).