Instruction manual
Installation
9
2. Installation
2.1 Technical characteristics
Water supply pressure min. 0,05 - max. 0,9 MPa (min. 0.5 – max. 9
bar)
Water supply temperature
max. 60°C
Capacity
12-13 standard place settings
Class of protection against
moisture
IPX0
Protection against electric shock
class I
Electrical data
see the data plate
Appliance dimensions (mm)
2.2 General Information
This appliance may be placed up against walls or other furniture units.
If the appliance is installed near a heat source, fit a special insulating panel to
prevent overheating and malfunction of the appliance.
To facilitate the installation procedure, the intake and drain hoses can be
positioned in any direction; make sure that the hoses are not kinked, crushed or
pulled too tightly.
A hole at least 8 cm in diameter is required to allow the power supply cable and
hoses to pass.
At the end of the installation, perform a short test of the appliance: open the water
tap and check that there are no leaks.
To install the dishwasher against the back wall, the hoses should be passed
through the lower area where there is a dedicated space for them.
Level the appliance on the floor using the appropriate Allen key to
regulate the adjustable feet. This operation is essential for ensuring
correct operation of the dishwasher.
Some models are equipped with only one adjustable foot at the rear, which
can be adjusted by turning the screw on the lower front part of the appliance.