Instruction manual

Installation
61
EN
5.7 Electrical connection
General information
Check the mains characteristics against the
data indicated on the plate. The
identification plate bearing the technical
data, serial number and brand name is
visibly positioned on the appliance. Do not
remove this plate for any reason. Perform
the ground connection using a wire that is
20 mm longer than the other wires.
The appliance can work in the following
modes: 220-240 V 1N~
Use a 3 x 1 mm² three-core cable.
Fixed connection
Fit the power line with an omnipolar circuit
breaker in compliance with installation
regulations. The circuit breaker should be
located near the appliance and in an easily
reachable position.
Connection with plug and socket
Make sure that the plug and socket are of
the same type. Avoid using adapters, gang
sockets or extensions as these could cause
overheating and a risk of burns.
Testing
At the end of installation, carry out a brief
inspection test. If the hob fails to operate,
after checking that you have carried out the
instructions correctly, unplug the appliance
and contact Technical Support.
Power voltage
Danger of electrocution
• Have the electrical connection
performed by authorised technicians.
• Use personal protective equipment.
• The appliance must be connected to
ground in compliance with electrical
system safety standards.
• Disconnect the mains power supply.
• Do not pull the cable to remove the
plug.
• Use cables withstanding a temperature
of at least 90°C.
• The tightening torque of the screws of
the terminal board leads must be
1.5-2Nm.
The values indicated above refer
to the cross-section of the internal
lead.