Instruction manual

Installation
60
The nozzles not provided are available at Authorised Service Centres.
8 LPG G30/G31 - 37 mbar AUX SR R UR2 (int + ext) UR3
Rated heating capacity (kW)
1.10 1.70 3.10 1.10 + 3.90 3.30
Nozzle diameter (1/100 mm)
48 60 80 48 + 89 82
Reduced flow rate (W)
400 450 750 400 + 1400 1600
Primary air (mm)
2 2 3 4 + 10 3
Rated flow rate G30 (g/h)
80 124 225 80 + 284 240
Rated flow rate G31 (g/h)
79 121 221 79 + 279 236
9 LPG G30/G31 - 50 mbar AUX SR R UR2 (int + ext) UR3
Rated heating capacity (kW)
1.10 1.70 3.10 1.10 + 3.90 3.30
Nozzle diameter (1/100 mm)
48 54 73 42 + 82 76
Reduced flow rate (W)
400 450 750 400 + 1400 1400
Primary air (mm)
2 2 2 3 + 10 2.5
Rated flow rate G30 (g/h)
80 124 225 80 + 284 240
Rated flow rate G31 (g/h)
79 121 221 79 + 279 236
10 Town gas G110 – 8 mbar AUX SR R UR2 (int + ext) UR3
Rated heating capacity (kW)
1.10 1.70 3.10 1.10 + 3.80 3.30
Nozzle diameter (1/100 mm)
132 165 240 132 + 290 250
Reduced flow rate (W)
400 450 750 400 + 1200 1400
Primary air (mm)
1 1 1.5 2 + 4 1,5