Installation Instructions

Installation
27
EN
Save the nozzles removed from the unit
along with these instructions for possible
future use.
For installation of the appliance at high
altitude, please consult your local gas
company for their recommendation on
the correct orifice sizes and any other
necessary adjustments that will provide
proper gas combustion at specified
altitudes.
Lubricating the surface burner gas
valves
Over time, the surface burner gas valves
may become stiff or jam. Clean them
internally and re-lubricate. This operation
must be carried out by a qualified
technician.
Conversion to natural gas
This appliance is shipped from the factory
for use with natural gas. If the appliance
was previously converted to propane gas,
you have to convert it back to natural gas.
Check the orifices for the right nozzles and,
if required, replace them. Adjust the
minimum gas flow.
The optimum setting is achieved when the
height of the small flame is approx.
1
/
8
"
(3 to 4 mm).
Set the pressure regulator for natural gas.
Turn the spring plate the other way around
as shown in “Setting the pressure regulator
for propane gas”.
Save the nozzles removed from the
appliance for future use.