Installation Instructions
Installation
27
EN
• Save the nozzles removed from the unit 
along with these instructions for possible 
future use.
• For installation of the appliance at high 
altitude, please consult your local gas 
company for their recommendation on 
the correct orifice sizes and any other 
necessary adjustments that will provide 
proper gas combustion at specified 
altitudes.
Lubricating the surface burner gas 
valves
Over time, the surface burner gas valves 
may become stiff or jam. Clean them 
internally and re-lubricate. This operation 
must be carried out by a qualified 
technician.
Conversion to natural gas
This appliance is shipped from the factory 
for use with natural gas. If the appliance 
was previously converted to propane gas, 
you have to convert it back to natural gas.
Check the orifices for the right nozzles and, 
if required, replace them. Adjust the 
minimum gas flow.
The optimum setting is achieved when the 
height of the small flame is approx. 
1
/
8
"
(3 to 4 mm).
Set the pressure regulator for natural gas.
Turn the spring plate the other way around 
as shown in “Setting the pressure regulator 
for propane gas”.
Save the nozzles removed from the 
appliance for future use.