Installation Instructions

Installation
22
Setting the pressure regulator for
propane gas
To convert the regulator to the type of gas
used, the following must be done:
1. Unscrew the cover of the pressure
regulator.
2. Unscrew the plastic regulator stem from the
regulator cap. Configuration “A” is for
Natural Gas.
3. Invert the plastic regulator stem to achieve
the configuration “B” for Propane Gas and
screw it in tightly.
4. Screw the regulator stem and cap into
place.
List of components
This conversion kit consists of the following
components:
One label for propane gas injectors
Four injectors Ø 0.94 mm for
the Reduced Rapid burner.
Two injectors Ø 0.48 mm for
the Ultra-rapid Dual burner
(internal crown).
Two injectors Ø 1.15 mm for the Ultra-
rapid Dual burner (external crown).
One change injectors warning label:
CAUTION
Before proceeding with the gas
conversion, the gas supply must be
turned off before disconnecting the
electrical power.