Installation Instructions
Installation
20
4. Retest for leaks. If no bubbles appear, 
the test is passed. Wipe off all residues 
of detection fluid.
Testing the electric ignition of the 
burner
This test should be performed after the 
range and supply line connectors have 
been carefully checked for leaks and the 
range connected to the electric power 
supply:
1. Push in and turn a surface burner knob to 
the low flame position. You will hear the 
igniter sparking.
2. The surface burner should light when gas 
is supplied to the cooktop burners. Each 
burner should light within four (4) 
seconds, after air has been purged from 
supply lines. Visually check that burner 
has lit.
3. Once the burner lights, the control knob 
should be rotated out of the low flame 
position.
4. There are separate ignition devices for 
each burner. Try each knob separately 
and together until all burner valves have 
been checked.
Minimum adjustment for natural Gas
Light the burner and turn the knob to the 
minimum position. Remove the gas tap knob 
and turn the adjustment screw at the side of 
the tap rod until the desired minimum flame 
is achieved. Refer to the following pictures.
• Dual Flame burner:
•Rapid burner:
Refit the knob and verify the correct ignition 
and burner flame stability (when turning the 
knob rapidly from the maximum to the 
minimum position the flame must not go out). 
Repeat this operation on the remaining gas 
taps on the cooktop.