1.4 Gas connection
The appliance is shipped from the factory 
for use with natural gas at a pressure of 5" 
of water column. When checking if the 
regulator is working properly, the inlet 
pressure must be at least 1" greater than the 
operating (manifold) pressure above. 
When used with natural gas, the pressure 
supplied to the regulator must be between 
6" and 10.5" of the water column. 
 WARNING: Explosion hazard
• Use a new AGA or CSA-certified 
connector.
• Install a manual shut-off valve.
• Securely tighten all gas connections.
• If connected to propane, have a 
qualified technician ensure that the gas 
pressure does not exceed a 14" W.C.P.
• Examples of qualified technicians include 
licensed heating personnel, authorized 
gas company personnel, and 
authorized service personnel.
• Failure to do so can result in loss of life, 
explosion, or fire.
NOTE: 
• Observe all codes and 
ordinances in force.
• The range must be connected to 
a standard gas supply.