User manual
Cleaning and maintenance
30
After having tightened the hose
connector(s), push the gas hose 6 onto the
hose connector and secure it with the clamp
5 that is compliant with the standard in
force.
Connection with a flexible steel hose
Make the connection to the gas mains
using a continuous flexible steel hose
attached to the wall that is in compliance
with the specifications indicated in current
regulations.
Carefully tighten the connector 3 to the gas
connector 1 of the appliance, inserting the
seal 2 supplied.
Connection with a steel hose with conical
fitting
Make the connection to the gas mains
using a continuous flexible steel hose
attached to the wall that is in compliance
with the specifications indicated in current
regulations.
Carefully screw the hose connector 3 to the
appliance’s gas connector 1 (½” thread
ISO 228-1), placing the supplied seal 2
between them. Apply insulating material to
the thread of connector 3, then tighten the
steel hose 4 to the connector 3.
Connection using a rubber hose
complying with current standards is
only permitted if the hose can be
inspected along its entire length.
The inside diameter of the hose
must be 8 mm for LPG and 13 mm
for Natural gas and Town gas.