8 LPG G30/31 - 30/37 mbar AUX SR UR3
Rated heating capacity (kW)
1.05 1.75 3.90
Nozzle diameter (1/100 mm)
50 65 100
Reduced flow rate (W)
400 500 1600
Pre-chamber (printed on nozzle)
---
Rated flow rate G30 (g/h)
76 127 284
Rated flow rate G31 (g/h)
75 125 279
9 LPG G30/31 - 37 mbar AUX SR UR3
Rated heating capacity (kW)
1.10 1.80 4.00
Nozzle diameter (1/100 mm)
50 65 94
Reduced flow rate (W)
400 500 1600
Pre-chamber (printed on nozzle)
---
Rated flow rate G30 (g/h)
80 131 291
Rated flow rate G31 (g/h)
79 129 286
10 LPG G30/31 - 50 mbar AUX SR UR3
Rated heating capacity (kW)
1.05 1.75 3.90
Nozzle diameter (1/100 mm)
43 58 77
Reduced flow rate (W)
400 500 1600
Pre-chamber (printed on nozzle)
H2 0264-1 S1
Rated flow rate G30 (g/h)
76 127 284
Rated flow rate G31 (g/h)
75 125 279
11 Town gas G110 – 8 mbar AUX SR UR3
Rated heating capacity (kW)
1.05 1.75 3.80
Nozzle diameter (1/100 mm)
145 185 340
Reduced flow rate (W)
400 500 1200
Pre-chamber (printed on nozzle)
/8 /2 -
12 Town gas G120 – 8 mbar AUX SR UR3
Rated heating capacity (kW)
1.05 1.75 3.90
Nozzle diameter (1/100 mm)
135 175 315
Reduced flow rate (W)
400 500 1200
Pre-chamber (printed on nozzle)
/8 /1 -