Instruction manual
Installation
59
EN
The nozzles not provided are available at Authorised Service Centres.
7 LPG G30/31 - 30/37 mbar AUX RR UR3
Rated heating capacity (kW)
1.05 2.50 3.90
Nozzle diameter (1/100 mm)
50 79 100
Reduced flow rate (W)
400 500 1600
Pre-chamber (printed on nozzle)
-H8-
Rated flow rate G30 (g/h)
76 182 284
Rated flow rate G31 (g/h)
75 179 279
8 LPG G30/31 - 37 mbar AUX RR UR3
Rated heating capacity (kW)
1.10 2.50 4.00
Nozzle diameter (1/100 mm)
50 75 94
Reduced flow rate (W)
400 800 1600
Pre-chamber (printed on nozzle)
---
Rated flow rate G30 (g/h)
80 182 291
Rated flow rate G31 (g/h)
79 179 286
9 LPG G30/31 - 50 mbar AUX RR UR3
Rated heating capacity (kW)
1.05 2.50 3.90
Nozzle diameter (1/100 mm)
43 65 77
Reduced flow rate (W)
400 800 1600
Pre-chamber (printed on nozzle)
H2 Z F4
Rated flow rate G30 (g/h)
76 182 284
Rated flow rate G31 (g/h)
75 179 279
10 Town gas G110 – 8 mbar AUX RR UR3
Rated heating capacity (kW)
1.05 2.50 3.80
Nozzle diameter (1/100 mm)
145 230 340
Reduced flow rate (W)
400 800 1200
Pre-chamber (printed on nozzle)
/8 /3 /13
11 Town gas G120 – 8 mbar AUX RR UR3
Rated heating capacity (kW)
1.05 2.50 3.90
Nozzle diameter (1/100 mm)
135 220 315
Reduced flow rate (W)
400 800 1200
Pre-chamber (printed on nozzle)
/8 /3 /13