Operation Manual

Instructions for the installer
23
Lift the hob top upwards.
10.2 Adjustment for LPG
Loosen screw A and push support B all the way. Using a a double head, remove
nozzle C and replace it with the appropriate nozzle, following the instructions in
the tables for the type of gas to be used. The nozzle tightening torque must be
no more than 3 Nm. Reposition support B so that nozzle C is covered perfectly.
Move the Venturi tube D to adjust the air flow until distance “X” is reached as
indicated in the table in paragraph “10.4 Primary air adjustment” and then
secure the tube by means of screw A. After the adjustments have been carried
out, restore the seals with sealing wax or equivalent material.
Burner
Rated
heating
capacity
(kW)
LPG G30/G31 28/37 mbar
Nozzle
diameter
1/100 mm
Reduced
capacity
(W)
Capacity
g/h G30
Capacity
g/h G31
Auxiliary (1) 1.1 48 400 80 79
Semi-rapid (2) 1.7 62 500 124 121
Rapid (3) 3.1 85 1000 225 221
Reduced Rapid (4) 2.6 76 750 189 186
Ultra-rapid (5) 3.5 87 1600 256 250
Double crown
Internal (6) 1.0 48 400 73 71
External (6) 3.2 85 1400 233 229