Instruction manual

EN
1
14
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to
the chimney using either a flexible or rigid
pipe ø 150 mm, the choice of which is left to the in-
staller.
Fix the pipe in position using sufficient pipe
clamps (not supplied).
Remove any activated charcoal filters.
ø 150
RECIRCULATION VERSION AIR OUTLET
Cut a hole ø 150 mm in the wall unit over the hood.
Connect the hood body outlet to the top part of the
wall unit using a rigid or flexible pipe ø 150 mm, to
be selected by the installer.
Fix the pipe in position using sufficient pipe clamps
(not supplied).
Ensure that the activated charcoal filters have been
inserted.
150
ELECTRICAL CONNECTION
Connect the hood to the mains through a two-pole switch having a contact gap of at least 3
mm.
When opening the sliding carriage for the first time after installing the hood, pull it out
briskly until it clicks.