Instruction manual

Installation
37
EN
Fixed connection
Fit the power line with an all-pole circuit
breaker with a contact separation distance
sufficient to provide complete disconnection
in category III overvoltage conditions,
pursuant to installation regulations. The
disconnection incorporated in the fixed
wiring must be compliant to AS/NZS 3000
regulations.
Overall dimensions
Location of electrical connection points.
5.3 For the installer
The plug must remain accessible after the
installation is complete. Do not kink or
trap the mains connection cable.
• The appliance must be fitted according
to the installation diagrams.
• In case the appliance fails to operate
correctly after all checks have been
carried out, refer to the Authorised
Assistance Centre in your area.
• When satisfied with the appliance,
please instruct the user on the correct
method of operation.