User Manual

Installation
30
N.G. The regulator supplied must be fitted
to the ½ BSP thread at the rear of the
appliance. An approved manual shut-off
valve must be installed. The N.G. regulator
must be checked and adjusted to 1.0kPa
after installation.
U.L.P.G. Can be connected to the inlet
fitting directly. The pressure must be
checked to ensure it is operating at
2.75kPa. A separate test point fitting must
be installed between the piping & the
appliance for the pressure to be checked to
ensure it is operating at 2.75kPa.
Connection to liquid gas
Use a pressure regulator and make the
connection on the gas cylinder following
the guidelines set out in the regulations in
force.
Make sure that the supply pressure
complies with the values indicated in
section “ Burner and nozzle characteristics
table”.
Room ventilation
The room containing the appliance should
have a permanent air supply in accordance
with the standards in force. The room where
the appliance is installed must have enough
air flow needed for the regular combustion
of gas and the necessary air change in the
room itself. The cooktop shall be installed in
rooms with natural ventilation, as required
by Standards regulations AS/NZS5601.
In case the appliance fails to
operate correctly after all checks
have been carried out, refer to the
authorised service provider in your
area.