User manual
Installation
23
EN
Gas connection
The appliance is shipped from the factory
for use with natural gas at a pressure of 5"
of water column. When checking if the
regulator is working properly, the inlet
pressure must be at least 1" greater than the
operating (manifold) pressure above.
When used with natural gas, the pressure
supplied to the regulator must be between
6" and 10.5" of the water column.
To convert the appliance to propane gas
see "Conversion to propane gas (LPG)".
The conversion must be done by a qualified
technician or installer. Use a flexible gas
pipe with a length of at least 5 ft (1.5 m).
The gas inlet to the unit is located at the
back right of the appliance. Install the
pressure regulator (supplied with the unit)
on the gas inlet. Install the gasket (supplied
with the unit) between the inlet and the
regulator. Position the regulator so that the
cap D is easily accessible. Tighten the nut
on the gas inlet so that it is hand tight plus
1/3 turn. Connect the gas pipe to the
regulator using Teflon tape or pipe-joint
compound (resistant to propane gas and
natural gas). Turn so that it is hand tight plus
1/3 turn. Do not exceed 1 turn for
alignment, to prevent possible damage to
the gas pressure regulator.
1 Gas inlet (attached to the appliance).
2 Gasket.
3 Pressure regulator.
WARNING: The tightening torque
of adapter (C / E) must not be
greater than 36 ozf - 10 Nm.
CAUTION
Do not allow regulator to rotate on pipe
when tightening fittings.
WARNING
Do not attempt to adjust the pressure
regulator, except when converting to
propane. Adjustments could lead to
leaks or cause incorrect gas pressure
being supplied to the appliance.