User manual
Conversion Kit
12
10 Combustion products
The combustion products may be extracted 
by means of hoods connected to a natural 
draught chimney whose efficiency is certain 
or via forced extraction. An efficient 
extraction system requires precision 
planning by a specialist qualified in this 
area and must comply with the positions 
and distances indicated by the applicable 
standards. 
When the job is complete, the installer must 
issue a certificate of conformity.
1 Extraction using a hood
2 Extraction without a hood
A Single natural draught chimney
B Single chimney with extractor fan
C Directly outdoors with wall- or window-
mounted extractor fan
D Directly outdoors through wall
 Air
 Combustion products
 Extractor fan
11 Final operations
• Completely fill out the conversion label 
(part no. 92849A078) and attach it to 
the rear of the appliance. Do not cover 
any other labels with the conversion 
label.
• Over time the gas taps may become 
difficult to turn and get blocked. Clean 
them internally and replace the 
lubrication grease.
• Save the nozzles removed from the unit 
along with these instructions for possible 
future use.
• For installation of the appliance at high 
altitude, please consult your local gas 
company for their recommendation on 
the correct orifice sizes and any other 
necessary adjustments that will provide 
proper gas combustion at specified 
altitudes.
12 Natural Gas
To convert back to Natural Gas, follow 
steps 1 through 7 and replace the nozzles 
in the order in which they were removed.
Lubrication of the gas taps should 
be performed by a specialised 
technician.