User manual
Conversion Kit
10
9 Final operations
• Completely fill out the conversion label 
(part no. 92849A078) and attach it to 
the rear of the appliance. Do not cover 
any other labels with the conversion 
label.
• Over time the gas taps may become 
difficult to turn and get blocked. Clean 
them internally and replace the 
lubrication grease.
• Save the nozzles removed from the unit 
along with these instructions for possible 
future use.
• For installation of the appliance at high 
altitude, please consult your local gas 
company for their recommendation on 
the correct orifice sizes and any other 
necessary adjustments that will provide 
proper gas combustion at specified 
altitudes.
10 Natural Gas
To convert back to Natural Gas, follow 
steps 1 through 7 and replace the nozzles 
in the order in which they were removed.
Lubrication of the gas taps should 
be performed by a specialized 
technician.