LP Conversion Kit Guide
Conversion Kit
6
3 Adaptation to different types of gas
To adapt the regulator to the type of gas used, 
the following must be done:
1. Unscrew the cover of the pressure 
regulator.
2. Unscrew the spring retainer from the cover.
3. Screw the spring retainer back on 
according to the type of gas used (see the 
following illustrations).
• Natural Gas: Set pressure to 5” W.C.P. 
Incoming line pressure of 6” - 10 1/2” 
W.C.P maximum.
• LP Gas: Set pressure to 10” W.C.P. 
Incoming line pressure 11”- 13” W.C.P. 
maximum.
• Incoming line pressure upstream from the 
regulator must be 1” (2.5 cm) W.C.P. 
higher than the manifold pressure in 
order to check the regulator.
The range must be isolated from the gas 
supply piping system by turning off the 
respective manual shut-off valve during any 
pressure testing of the gas supply piping 
system at test pressures equal to or greater 
than 1/2 PSIG (3.5 kPa).
4 Replacing the rangetop's burners
nozzles:
1. Remove all the grates and all the burner 
caps (1) and heads (2); 
2. Unscrew the burner nozzles with a 7 mm 
socket wrench;