User manual
Installation
8
1 Installation
1.1 Dimension Requirements
1. min. clearance from the sides of range to 
side wall or other combustible material;
2. min. cabinet opening width;
3. upper cabinet to countertop;
4. min. when bottom of wood or metal 
cabinet is protected by not less than ¼” 
(0.64 cm) flame retardant millboard 
covered with not less than No. 28 MSG 
sheet steel, 0.015" (0.4 mm) stainless 
steel, 0.024" (0.6 mm) aluminum or 
0.020" (0.5 mm) copper. 35" (889 mm) 
min. clearance between the top of the 
cooking surface and the bottom of an 
unprotected wood or metal cabinet.
5. max. upper cabinet depth.
Y - Grounded outlet
Position within 11 
7
/
8
" (300 mm) from the 
left rear corner of the range.
X - Gas supply line
Position within 11 
7
/
8
" (300 mm) from the 
right rear corner of the range.
A 766 mm
30 
3
/
16
"
B 636 mm 25“
C
1
216 mm
8 
1
/
2
"
G
2
766 mm
30 
3
/
16
"
I
3
457 mm 18"
L
4
610 mm 24"
M
5
330 mm 13"
N 150 mm
5 
15
/
16
"
NOTE: Install with zero 
clearance sides and back.