Installation Instructions
Installation
19
EN
Incoming line pressure
Incoming line pressure upstream from the 
regulator must be 1” (2.5 cm) W.C.P. higher 
than the manifold pressure in order to check 
the regulator. Incoming line pressure to the 
regulator should be as follows for operation 
and checking the regulator setting:
• Natural Gas: Set pressure to 5” W.C.P. 
Incoming line pressure of 6” - 10 1/2” 
W.C.P maximum.
• LP Gas: Set pressure to 10” W.C.P. 
Incoming line pressure 11”- 13” W.C.P. 
maximum.
Lubricating the surface burner gas valves
Over time, the surface burner gas valves 
may become stiff or jam. Clean them 
internally and relubricate. This operation 
must be carried out by a qualified 
technician.
NOTE: The range must be isolated 
from the gas supply piping system 
by turning off the respective 
manual shut-off valve during any 
pressure testing of the gas supply 
piping system.