Installation Instructions
Installation
18
Due to problems of overall dimensions at 
the back, screw in the pressure regulator so 
that it is sloped at 45° vs the wall at the 
back of the appliance. 
Test the appliance
Follow these instructions to leak test the 
appliance:
Use a brush and liquid detergent to test all 
gas connections for leaks. Bubbles around 
connections indicate a leak. If a leak 
appears, shut off the gas valve controls and 
adjust the connections. Then check the 
connections again. Remove all the 
detergent product from the range. Replace 
the parts on the burner and turn the knobs 
on the gas tap valves.
NEVER TEST FOR GAS LEAKS WITH A 
MATCH OR OTHER FLAMES.
Shut-off valve
The supply line must be fitted with an 
approved shut-off valve.
This valve should be located in the same 
room as the range and should be in a 
location where it can be easily opened and 
closed.
Do not block access to the shut-off valve. 
The valve is necessary for turning the gas to 
the appliance on or off.