Installation Instructions
Installation
17
EN
This installation must conform with all local 
codes and ordinances. In the absence of 
local codes, installation must conform to 
American National Fuel Gas Code, ANSI 
Z223.1/NFPA 54 or, in Canada, the 
Natural Gas and Propane Installation 
Code, CSA B149.1.
If local codes permit, a flexible metal 
appliance conductor with the new AGA or 
CSA design certified, 4-5 feet (1.2-1.5 m) 
long, 
1
/
2
" or 
3
/
4
" ID NPT, is 
recommended for connecting this range to 
the gas supply line.
Do not bend or damage the flexible 
connector when moving the range. The 
pressure regulator has 3/8" female pipe 
threads. You will need to determine the 
fittings required, depending on the 
dimension of your gas supply line, the 
flexible metal connector and the shut-off 
valve.
The appliance should be installed in rooms 
that have a permanent air supply in 
accordance with the standards in force. The 
room where the appliance is installed must 
have enough air flow for the regular 
combustion of gas and the necessary air 
change in the room itself. The air vents, 
protected by grilles, must be the right size to 
comply with current regulations and 
positioned so that no part of them is 
obstructed, not even partially. 
The room must be kept adequately 
ventilated in order to eliminate the heat and 
humidity produced by cooking: in 
particular, after prolonged use, you are 
recommended to open a window or to 
increase the speed of any fans.
Gas connection
Connect the adapter C (ISO 228/1 -
 ½ NPT) to the gas inlet of the appliance A 
being sure to insert the supplied gasket B.
Apply a suitable sealing substance (such as 
Teflon tape) between pressure regulator D 
and adapter C.
Connect the pressure regulator D to the 
adapter C put on in the previous step (the 
arrow on the back of the regulator points 
towards the gas inlet of the appliance).
Apply a suitable sealing substance (such as 
Teflon tape) between pressure regulator D 
and adapter E (½ NPT - ½ NPT) (not 
supplied). 
Connect the adapter E to the pressure 
regulator D.
WARNING: The tightening torque 
of adapter (C / E) must not be 
greater than 36 ozf - 10 Nm.