Installation Instructions
Installation
16
Recommended Grounding Method
For your personal safety, this range must be 
grounded. This range is equipped with a 3-
prong grounding plug. To minimize possible 
shock hazard, the cord must be plugged 
into a mating 3-prong grounding 
receptacle, grounded in accordance with 
the National ANSI/NFPA 70 Electrical 
Code (latest edition*) or the Canadian 
Electrical Code (CSA)** and local codes 
and ordinances. lf a mating receptacle is 
not available, it is the personal responsibility 
and obligation of the customer to have a 
properly polarized and grounded 3-prong 
outlet installed by a qualified electrician.
1.6 Gas supply requirements
Copies of the standards listed 
above may be obtained from:
* National Fire Protection 
Association, 1 Batterymarch Park, 
Quincy, Massachusetts 02169-
7471
** CSA International, 8501 East 
Pleasant Valley Road, Cleveland 
OH 44131-5575
Warning
Explosion hazard
• Use a new AGA or CSA-approved gas 
supply line.
• Install a shut-off valve.
• Securely tighten all gas connections.
• lf connected to LP, have a qualified 
technician ensure that the gas pressure 
does not exceed a 14" W.C.P.
• Examples of qualified technicians 
include licensed heating personnel, 
authorized gas company personnel, 
and authorized service personnel.
• Failure to do so can result in loss of life, 
explosion, or fire.
NOTE: 
• Observe all codes and 
ordinances in force.
• The range must be connected to 
a standard gas supply.