Technical data

56
Instructions for the installer
12. ADAPTATION TO DIFFERENT TYPES OF GAS
BEFORE PERFORMING ANY OPERATIONS, SWITCH OFF THE POWER SUPPLY TO THE
APPLIANCE.
Appliance set for gas: NATURAL GAS G20 (2H) 20 mbar pressure (see label on product)
In the case of operation with other types of gas, the burner nozzles must be changed and the minimum
flame adjusted on the gas taps.
To change the nozzles, proceed as described in the following paragraphs.
12.1 Replacing the hob nozzles
1 Remove the pan stands, and remove all burner caps and flame-spreader
crowns to access the burner casings.
2 Unscrew the nozzles using a 7 mm socket wrench.
3 Replace the burner nozzles according to the type of gas to be used (see
12.3 Burner and nozzle characteristics tables).
4 Replace the burners in the correct position.
12.2 Arrangement of burners
Burner
Auxiliary
Semi-rapid
Rapid
Ultra-rapid