Operation Manual

Instructions for the installer
83
4. ADAPTATION TO DIFFERENT TYPES OF GAS
Before carrying out the following operations, disconnect the appliance from the electricity supply.
The appliance is preset for natural gas G20/25 at a pressure of 20/25 mbar. In the case of operation
with other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas
taps. To change the nozzles, proceed as described in the following paragraphs.
4.1 Replacement of nozzles on the cooking hob
1 Extract the pan stands and remove all the caps and flame-spreader crowns;
2 Unscrew the burner nozzles with a 7 mm socket wrench;
3 Replace the burners in the correct positions.