Datasheet

V
EXH
P
Screw-in type
VAC.SUP.
EXH.
:=@;.
>
B
How to Order
In-line Type Vacuum Ejector
ZU A Series
ZU S05 A
Nozzle diameter
05
0.5 mm
07
0.7 mm
Vacuum pressure reached
S
-90 kPa
L
-48 kPa
Port size
Ø 6 One-touch fi tting
01
Rc 1/8 female thread
Operating temperature range
-5 to 50 °C (No freezing)
Fluid
Air
Applicable tubing material
FEP, PFA, Nylon, Soft nylon, Polyurethane
Operating pressure range
0.1 to 0.6 MPa
Standard supply pressure
0.45 MPa
Specifi cations
Construction
Symbol
Ejector Specifi cations
1
Model
Nozzle
diameter
[mm]
Vacuum pressure
reached
2
[kPa]
Maximum suction
ow rate
2
[l/min(ANR)]
Air
consumption
2
[l/min(ANR)]
Weight
[g]
Type S Type L Type S Type L
One-touch
connection
Screw-in
connection
ZU05A
0.5
−90 −48
7 13 14 3.9 18.6
ZU07A
0.7 11 16 28 4.3 19.1
1 The values indicating characteristics are representative values, and may vary depending on
the atmospheric pressure (weather, altitude, etc.).
2 Supply pressure: 0.45 MPa
Component Parts
No. Description
Material Note
1 Body
PBT
2 Diffuser
PBT Type S: White, Type L: Black
3 Cap
POM
4 O-ring
NBR Grease applied
5 Cassette
6 Seal
NBR Grease applied
7 Screw-in stud
Brass Electroless nickel plating
RoHS
Precautions
Be sure to read this before handling
the products. Refer to the back cov-
er for safety instructions. For vacu-
um equipment precautions, refer to
the “Handling Precautions for SMC
Products” and the “Operation Manu-
al” on the SMC website: http://www.
smc.eu
Mounting
Caution
1 .
When the product is mounted in between
piping, the piping on both the P port and
V port should be adequately supported
to avoid causing unnecessary loading
and stressing of the product which may
lead to performance issues or damage to
the body of the product.
When mounting the product, please do
not block the exhaust port at the centre
of the body as this may cause performance
issues.
Piping
Caution
1. Piping diameter
The piping diameter for each port should be the
standard size of One-touch fitting. If the piping
diameter is reduced, it may lead to insufficient
flow of supply air, reduction of suction flow and
reduction in the vacuum pressure.
Model Selection
Caution
1. Supply valve
Select the supply valve which can supply suffi-
cient flow rate compared with the ejector air
consumption. If the flow rate of the supply valve
is insufficient, it may lead to vacuum failure. The
selected supply valve should at least have the C
factor shown in the table below.
Minimum C Factor of a Supply
Valve
Model C [dm
3
/(s·bar)]
ZU05
0.12
ZU07
0.23
Air Supply
Caution
1. Quality of supply air
Use clean compressed air as fluid. (Air quality
class 2 : 4 : 3, 2 : 5 : 3, or 2 : 6 : 3 as specified in
ISO 8573-1: 2010 is recommended.)
If impurity enters the product, vacuum perfor-
mance might be reduced due to deterioration of
air passage and clogging of exhaust system.
1