Specifications
Note) If the applied voltage fluctuates around the set-value, the hysteresis must be set to a value more than the fluctuating width, otherwise chattering will occur.
Model
ZSE10
(vacuum pressure)
Rated pressure range
Set pressure range/Pressure display range
Withstand pressure
Minimum unit setting
Fluid
Power supply voltage
Current consumption
Switch output
Repeat accuracy
Analog
output
Hysteresis
Display
Display accuracy
Indicator light
Environmental
resistance
Temperature characteristics
Lead wire
Standard
0.0 to –101.0 kPa
10.0 to –105.0 kPa
500 kPa
0.1 kPa
0.6 to 5 V
±2.5% F.S.
ZSE10F
(compound pressure)
–100.0 to 100.0 kPa
–105.0 to 105.0 kPa
500 kPa
0.1 kPa
Air, Non-corrosive gas, Non-flammable gas
12 to 24 VDC
±10%, Ripple (p-p) 10% or less (With power supply polarity protection)
40 mA or less
NPN or PNP open collector 2 outputs (Selectable)
80 mA
28 V (With NPN output)
2 V or less (With load current of 80 mA)
2.5 ms or less (Response time selections with anti-chattering function: 20, 100, 500, 1000, 2000 ms)
Yes
±0.2% F.S. ±1 digit
Variable (0 or above)
Note)
±1% F.S. or less
Approx. 1
k
3 1/2 digit, 7-segment indicator, 1-colour display (Red)
±2% F.S. ±1 digit (at 25°C ±3°C ambient temperature)
Lights up when output is turned ON. OUT1: Green OUT2: Red
IP40
Operating: –5 to 50
°C, Stored: –10 to 60°C (No freezing or condensation)
Operating and stored: 35 to 85% RH (No condensation)
1000 VAC for 1 min. between live parts and enclosure
50 M or more between live parts and enclosure (at 500 VDC Mega)
10 to 150 Hz, at the smaller of amplitude 1.5 mm or 20 m/s
2
in X, Y, Z directions for 2 hours each (De-energized)
100 m/s
2
in X, Y, Z directions 3 times each (De-energized)
±2% F.S. (at 25°C in an operating range of –5 to 50°C)
CE Marking, UL (CSA), RoHS compliant
ISE10
(positive pressure)
–0.100 to 1.000 MPa
–0.105 to 1.050 MPa
1.5 MPa
0.001 MPa
Maximum load current
Maximum applied voltage
Residual voltage
Response time
Short circuit protection
Voltage
output
Hysteresis mode
Window comparator mode
Enclosure
Operating temperature range
Operating humidity range
Withstand voltage
Insulation resistance
Vibration resistance
Impact resistance
1 to 5 V ±2.5% F.S.
Output voltage (Rated pressure range)
Linearity
Output impedance
Oil-resistant vinyl cabtire cable
5 cores, Cross section: 0.15 mm
2
(AWG26) Insulator O.D.: 1.0 mm
Piping Specifications
Model
M5 M5R
Sensor pressure receiving area: Silicon
M5 x 0.8
(Rear ported)
01
R1/8
(Side ported)
N01
NPT1/8
(Side ported)
M5 x 0.8
(Side ported)
Sensor pressure receiving area
Piping port
With lead wire with connector (5 cores, 2 m)
Without lead wire with connector
C3604 (Electroless nickel plated)
O-ring: HNBR
55 g
15 g
63 g
23 g
Port size
Wetted
part
material
Mass
Function
(Details Pages 8 and 9)
Copy function
Auto-preset function
Precision indicator setting function
Peak display function
Bottom display function
Key lock function (Selectable secret code)
Zero-clear function
Anti-chattering function
Display unit switching function
Power-saving mode
Display resolution conversion function
kPaMPa conversion function
The settings of the master pressure switch can be copied to the slave pressure switches.
This function is to calculate a rough set value automatically based on the on-going operation.
The scattering of the indicated value can be eliminated.
Can retain the maximum pressure value displayed during measurement.
Can retain the minimum pressure value displayed during measurement.
Key operation can be locked to prevent any incorrect function of the operation switch.
The pressure display can be set at zero when the pressure is open to the atmosphere.
Prevents possible malfunction due to sudden fluctuations in the primary pressure by adjusting the response time.
Can convert the display value.
Reduces power consumption.
The unit can be changed between kPa and MPa.
Changes the display resolution from the default value 1000 to 100.
The flickering on the display can be eliminated.
Series ZSE10
(
F
)
/ISE10
Brown DC (+)
Black OUT1
White OUT2
FUNC
Note)
Blue DC (–)
Load
Load
+
12 to
24 VDC
+
12 to
24 VDC
+
12 to
24 VDC
+
12 to
24 VDC
Brown DC (+)
Black OUT1
White OUT2
FUNC
Note)
Blue DC (–)
Load
Load
Max. 80 mA
Residual voltage 2 V or less
Max. 28 V, 80 mA
Residual voltage 2 V or less
Load
Load
Brown DC (+)
Black OUT1
Blue DC (–)
FUNC
Note)
White OUT2
Max. 28 V, 80 mA
Residual voltage 2 V or less
Analogue voltage output
Output impedance approx. 1 k
Load
Load
Brown DC (+)
Black OUT1
Blue DC (–)
FUNC
Note)
White OUT2
Max. 80 mA
Residual voltage 2 V or less
Analogue voltage output
Output impedance approx. 1 k
LED
button (UP)
button (SET)
button (DOWN)
Output (OUT1)
indicator (Green)
Output (OUT2)
indicator (Red)
Connector
terminal
Lead wire with connector
Main circuit
Main circuit
Main circuit
Main circuit
Range
For vacuum pressure
For compound pressure
For positive pressure
Rated pressure range
0.0 to –101.0 kPa
–100.0 to 100.0 kPa
–0.100 to 1.000 MPa
A
–0.1 kPa
B
0
–100 kPa
0
C
–101 kPa
100 kPa
1 MPa
Descriptions
Analogue Output
Voltage output
1
0.6
Pressure
5
BA C
Analogue output [V]
Output (OUT1) indicator (Green)
Output (OUT2) indicator (Red)
LED
button (UP)
button (DOWN)
button (SET)
Lights up when switch output (OUT1) is turned ON.
Lights up when switch output (OUT2) is turned ON.
Displays the current pressure, set mode, and error code.
Use this button to select the mode or increase the ON/OFF set-value.
Use this button to switch to the peak display mode.
Use this button to select the mode or decrease the ON/OFF set-value.
Use this button to switch to the bottom display mode.
Use this button to change the mode or finalize the set-value.
Internal Circuits and Wiring Examples
ZSE10
(
F
)
/ISE10
Output
specifications
NPN (2 outputs)
A
PNP (2 outputs)
B
Note) The FUNC terminal is connected when using the copy function. (Refer to “Copy function” on page 8.)
NPN (1 output) + Analogue voltage output
C E
PNP (1 output) + Analogue voltage output
Digital Pressure Switch
Series ZSE10(F)/ISE10
3