Brochure

Master
Slave
(Max. 10 switches)
1 switch 2 switches 10 switches
DC (+)
OUT1
OUT2
FUNC
DC (–)
Grey (copy line)
Blue
Brown
DC (+)
OUT1
OUT2
FUNC
DC (–)
Grey (copy line)
Blue
Brown
DC (+)
OUT1
OUT2
FUNC
DC (–)
Grey (copy line)
Blue
Brown
DC (+)
OUT1
OUT2
FUNC
DC (–)
Grey (copy line)
Blue
Brown
Power supply
Slave pressure switch
1 switch 2 switches
n
(Max. 10 switches)
Master
pressure switch
Function Details
Note) When the precision indicator setting function is used,
the set pressure value may change ±1 digit.
C
Precision indicator setting function (F 6)
0
Applied pressure
+
Displayed value at the
time of shipment
Adjustable range of display
calibration function
±5% R.D.
Display pressure value
D
Peak and bottom display function
E
Key lock function
This function prevents incorrect operations such as accidentally
changing the set-value.
F
Zero-clear function
This function clears and resets the zero value on the display of mea-
sured pressure.
For the pressure switch with analogue output, the analogue output
shifts according to the indication. A displayed value can be adjusted
within ±7% F.S. of the pressure when ex-factory. (ZSE10F (for
compound pressure) ±3.5% F.S.)
B
Auto-preset function (F 5)
Auto-preset function, when selected in the initial setting, calculates and stores the set-value from the measured pressure.
The optimum set-value is determined automatically by repeating vacuum and break with the target workpiece several times.
Fine adjustment of the indicated value of the pressure sensor can be
made within the range of ±5% of the read value.
(The scattering of the indicated value can be eliminated.)
Suction Verification
Work 1 Work 2
Work 1 Work 2 Work n
Work n
High
Vacuum
Max.
A
P
-
1
n
-
1
Min.
B
Atmosphere
Suction
Released
H
-
1
P_1 (P_2) = A (A-B)/4
n_1 (n_2) = B + (A-B)/4
P_1 or P_2 H_1 or H_2
H_1 (H_2) = (A-B)/2
Formula for Obtaining the Set-Value
A
Copy function (F97)
The settings of the master pressure switch can be copied to the slave pressure switches.
This can reduce the labour for setting and prevent the entry of incorrect set-values.
The set-value can be copied to up to 10 switches simultaneously.
(Maximum communication distance 4 m)
1) Connect the power supply and copy line as shown in the
left figure.
2) Select the slave switch which is to be the master, and
change it into a master using the buttons. (In the default
setting, all switches are set as slaves.)
3) Press the button of the master switch to start copying.
This function constantly detects and updates the maximum (mini-
mum) value and allows to hold the maximum (minimum) pressure
value.
When the buttons are simultaneously pressed for 1 second or
longer, while “holding”, the hold value will be reset.
Series ZSE10
(
F
)
/ISE10
H
Anti-chattering function (F 3)
A large bore cylinder or ejector consumes a large volume of air in operation and may expe-
rience a temporary drop in the supply pressure. This function prevents detection of such
temporary drops in the supply pressure as an error.
<Principle>
This function averages pressure values measured during the response time set by the user and then compares the average pressure value with
the pressure set point value to output the result on the switch.
Pressure
Momentary change
t (ms) t (ms)
Time
Time
Time
<Averaging> <Averaging>
Switch output
operation in
normal
conditions
ON
OFF
Switch output
operation when
anti-chattering
function is on.
ON
OFF
Set-value
P
-
1
H
-
1
Available response time settings
20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms
I
Display unit switching function (F 0)
Display units can be switched with this function.
Note) The ZSE10 (vacuum pressure) and ZSE10F (compound pressure)
will have different setting and display resolution when the unit is set
to MPa.
Display unit
Min. unit setting
kPa
MPa
Note)
PA
kgf/cm
2
GF
bar
bAr
psi
PSi
inHg
inH
0.1 0.001 0.001 0.001 0.01 0.1 1
1 0.001 0.01 0.01 0.1
0.1 0.001 0.001 0.001 0.02 0.1 1
mmHg
mmH
ZSE10
(vacuum pressure)
ZSE10F
(compound pressure)
ISE10
(positive pressure)
G
Error indication function
Note) If the above remedy cannot recover the operation, ask SMC for repair.
DescriptionError codeError name
Overcurrent error
Zero-clear error
Applied pressure
error
System error
Remedy
Load current of switch output (OUT1) exceeds 80 mA.
Turn the power off and remove the output factor for
the over current. Then turn the power on.
Reset applied pressure to a level within the set
pressure range.
Perform zero-clear operation again after restoring
the applied pressure to an atmospheric pressure
Load current of switch output (OUT2) exceeds 80 mA.
Supply pressure exceeds the maximum set pressure.
Supply pressure is below the minimum set pressure.
Internal data error
During zero-clear operation, pressure over ±7% F.S. is applied.
(ZSE10F (compound) ±3.5% F.S.)
After 1 s, the mode will reset to measurement mode. ±1% F.S. of
the zero-clear range varies between individual products.
Turn the power off and turn it on again. If the failure
cannot be solved, ask SMC for repair.
J
Power-saving mode (F80)
Power-saving mode can be selected.
It shifts to the power-saving mode without button operation for 30 se-
conds. It is set to the normal mode (Power-saving mode is OFF.)
when ex-factory. (Decimal points and operation indicator light (only
when the switch output is turned ON.) blink in the power-saving mo-
de.)
K
Secret code setting (F81)
It can be set whether code number input is required or not when key
is locked. It is set to input no code number when ex-factory.
The F in ( ) shows the function code number. Refer to the Operation
Manual for the details of operation procedures and function codes.
Digital Pressure Switch
Series ZSE10(F)/ISE10
9