Datasheet
Flow-rate Characteristics
Symbol
N.O.
2
1
Normally Open (N.O.)
Fluid and Ambient Temperature
Valve Leakage Rate
Note) Dew point temperature: –10°C or less
Ambient temperature [°C]
−20 to 60
Fluid temperature [°C]
−10
Note)
to 60
Note 1)
The operation of the valve may be unstable due to the capacity of the pressure supply source such as pumps and compressors or the pressure loss by
the orifice of piping. Please contact SMC to check if the required valve size can be used in the application. Please contact SMC for the compatibility of
the circuit flow and valve size.
(Refer to page 21.)
Note 2) Weight of grommet type. Add 10 g for conduit, 30 g for DIN terminal, and 60 g for conduit terminal type respectively.
¡Refer to “Glossary of Terms” on page 28 for details on the max. operating pressure differential.
Port size
(Nominal
diameter)
Body
material
Orifice diameter
[mmø]
Min. operating
pressure
differential
Note 1)
[MPa]
Max. operating pressure
differential [MPa]
AC DC
Model
Max. system
pressure
[MPa]
C
[dm
3
/(s·bar)]
bCv
Flow-rate characteristics
Weight
[g]
Effective area
[mm
2
]
0 0.7 0.6
10
15
20
25
Aluminium
Resin
C37 (Brass)
,
Stainless
steel
1.7
1.2
2.0
2.4
2.6
6.0
9.4
0.38
0.44
0.43
0.34
0.26
6.2
5.3
8.0
8.5
9.3
23.0
36.0
VXZ2A0
VXZ2B0
VXZ2C0
VXZ2D0
ø10
ø3/8"
ø12
1/4 (8A)
3/8 (10A)
1/2 (15A)
3/4 (20A)
1 (25A)
1.5
430
630
750
1150
1350
—
185—
Internal Leakage
Note 1) Leakage is the value at ambient temperature 20°C.
NBR, FKM
Seal material
Leakage rate (Air)
Note 1)
15 cm
3
/min or less (Aluminium body type)
15 cm
3
/min or less (Resin body type)
1 cm
3
/min or less (Metal body type)
NBR, FKM
Seal material
Leakage rate (Air)
Note 1)
15 cm
3
/min or less (Aluminium body type)
15 cm
3
/min or less (Resin body type)
1 cm
3
/min or less (Metal body type)
External Leakage
For Air
When the valve is closed, flow is blocked from
port 1 to port 2. However, if the pressure in port
2 is higher than port 1, the valve will not be able
to block the fluid and it will flow from port 2 to
port 1.
Zero Differential Pressure Type
Pilot Operated 2 Port Solenoid Valve
Note 2)
Series VXZ
For Air
Specifications
For Water
For OilOptions
Construction
Dimensions
For Heated Water
For High
Temperature Oil
5