Datasheet

View A-A
(Internal connection diagram)
− Mark
+ Mark
Round head combination screw
M3 Tightening torque 0.5 to 0.6 N·m
2
-
1
+
Round head combination screw
M3
Tightening torque 0.5 to 0.6 N·m
Terminal cover
A
Conduit terminal
G1/2
Tightening torque
0.5 to 0.6 N·m
A
Conduit terminal
In the case of the conduit terminal, make connections
according to the marks shown below.
· Use the tightening torques below for each section.
· Properly seal the terminal connection (G1/2) with the special
wiring conduit etc.
Class B coil: AWG20 Insulator O.D. 2.5 mm
Class H coil: AWG18 Insulator O.D. 2.1 mm
Lead wire
q
Seal
Wiring conduit
(Bore size G1/2 Tightening torque 0.5 to 0.6 N·m)
w
Conduit
When used as an IP65 equivalent, use seal to install the wiring
conduit. Also, use the tightening torque below for the conduit.
There is no polarity.
(For the power saving type, there is polarity.)
Note) Please order separately.
Rated voltage
DC
100 VAC
200 VAC
Other AC
q
Black
Blue
Red
Grey
w
Red
Blue
Red
Grey
Lead wire colour
Description
Seal VCW20-15-6
Part no.
q
w
Rubber seal
Washer
Connector
Binding head screw with flange
Tightening torque 0.5 to 0.6 N·m
Gasket
Binding head screw
Tightening torque 0.5 to 0.6 N·m
Compatible cable
Note)
(Cable O.D. ø6 to ø12 mm)
2
3
+
1
2: −
(+)
1: +
(−)
DIN terminal
Since internal connections are as shown below for the DIN
terminal, make connections to the power supply accordingly.
Caution
Grommet
Class B coil: AWG20 Insulator O.D. 2.5 mm
Class H coil: AWG18 Insulator O.D. 2.1 mm
There is no polarity.
· Use compatible heavy duty cords with cable O.D. of ø6 to 12 mm.
· Use the tightening torques below for each section.
Rated voltage
DC
100 VAC
200 VAC
Other AC
q
Black
Blue
Red
Grey
w
Red
Blue
Red
Grey
Lead wire colour
Terminal no.
DIN terminal
1
+ (−)
2
− (+)
Note) For an outside cable diameter of ø9 to 12 mm, remove the internal
parts of the rubber seal before using.
There is no polarity.
Electrical Connections
[Change of electrical entry]
Wire entry can be changed by mounting the housing in either
direction (four directions at every 90° ) after dividing the terminal
block and the housing.
For the indicator lighted style, be careful not to damage the light with
the lead wire of the cable.
Series VXZ
Specific Product Precautions 5
Be sure to read before handling. Refer to back cover for Safety Instructions, “Handling
Precautions for SMC Products” (M-E03-3) and the Operation Manual for 2 Port Solenoid Valves
for Fluid Control Precautions. Please download it via our website, http://www.smcworld.com
39