Datasheet
Standard Specifications
Valve
specifications
Coil
specifications
Valve construction
Withstand pressure
Body material
Seal material
Enclosure
Environment
AC
DC
Solenoid Coil Specifications
VXZ23, 24
VXZ25, 26
Model
7
10.5
Power consumption [W]
Note 1)
55
65
Temperature rise [°C]
Note 2)
Note 1) Power consumption, Apparent power: The value at ambient temperature of 20°C and when the rated voltage is applied. (Variation: ±10%)
Note 2) There is no difference in the frequency and the inrush and energized apparent power, since a rectifying circuit is used in the AC (Built-in full-wave
rectifier type).
Note 3) The value at ambient temperature of 20°C and when the rated voltage is applied. The value depends on the ambient environment. This is for
reference.
Note 1) Power consumption, Apparent power: The value at ambient temperature of 20°C and when the rated voltage is applied. (Variation: ±10%)
Note 2) The value at ambient temperature of 20°C and when the rated voltage is applied. The value depends on the ambient environment. This is for
reference.
Model
8.5
12.5
70
70
Power consumption [W]
Note 1)
Temperature rise [°C]
Note 2)
Normally Closed (N.C.)
DC Specification
Class B
Normally Open (N.O.)
DC Specification
Class B
AC (Built-in full-wave rectifier type)
DC
Be sure to read “Specific Product Precautions” before handling.
Series VXZ
Common Specifications
Zero differential pressure type pilot operated 2 port diaphragm type
2.0 MPa (Resin body type 1.5 MPa)
Aluminium, Resin, C37 (Brass), Stainless steel
Note 1)
NBR, FKM, EPDM
Dust-tight, Water-jet-proof type (equivalent to IP65)
Note 2)
Location without corrosive or explosive gases
24 VAC, 48 VAC, 100 VAC, 110 VAC, 200 VAC, 220 VAC, 230 VAC, 240 VAC,
12 VDC, 24 VDC
±10% of rated voltage
10% or less of rated voltage
2% or less of rated voltage
Class B (for air, water, oil), Class H (for heated water, high temperature oil)
Rated voltage
Allowable voltage fluctuation
Allowable leakage
voltage
Coil insulation type
Note 1) Aluminium body and resin body are available only for the VXZ2 .
Note 2) Electrical entry “Faston” type terminal is IP40.
3
A
VXZ2A, 2B
VXZ2C, 2D
VXZ23, 24
VXZ25, 26
Model
9.5
12
Apparent power [VA]
Note 1) 2)
70
70
Temperature rise [°C]
Note 3)
Model
10
14
70
70
Apparent power [VA]
Note 1) 2)
Temperature rise [°C]
Note 3)
Normally Closed (N.C.)
AC Specification (Built-in Full-wave Rectifier Type)
Class B
Normally Open (N.O.)
AC Specification (Built-in Full-wave Rectifier Type)
Class B
VXZ2A, 2B
VXZ2C, 2D
VXZ23, 24
VXZ25, 26
Model
12
15
Apparent power [VA]
Note 1) 2)
100
100
Temperature rise [°C]
Note 3)
Model
12
15
100
100
Apparent power [VA]
Note 1) 2)
Temperature rise [°C]
Note 3)
Class H Class H
VXZ2A, 2B
VXZ2C, 2D
VXZ23, 24
VXZ25, 26
Model
12
15
Power consumption [W]
Note 1)
100
100
Temperature rise [°C]
Note 2)
Model
12
15
100
100
Power consumption [W]
Note 1)
Temperature rise [°C]
Note 2)
Class H Class H
VXZ2A, 2B
VXZ2C, 2D
When pressure differential is less than 0.01 MPa, operation may become unstable. Please contact SMC in case of low flow
operation. (Refer to page 21.)