Specific Product Precautions 1
Be sure to read before handling. Refer to back cover for Safety Instructions, “Handling 
Precautions for SMC Products” (M-E03-3) and the Operation Manual for 2 Port Solenoid Valves 
for Fluid Control Precautions. Please download it via our website, http://www.smcworld.com
Design
Warning
Selection
Warning
Selection
Warning
Applicable Fluid
For Air
For Water
For Oil
For Heated water
For High temperature oil
Air
Air, Water
Air, Water, Oil
Air(up to 99
°C
), Water, Heated water
Air(up to 99°C), Water, Oil, High temperature oil
1. Usage with low flow
Unstable flow may occur with the product under the 
FOLLOWING CONDITIONS s LOW FLOW FROM THE PUMP OR
COMPRESSOR ETC s USE OF SEVERAL ELBOWS OR TEES IN THE
CIRCUITOR s THINNOZZLESINSTALLEDAT THEENDOFTHE PIPING
etc. This can cause valve opening/closing failure, or 
oscillation, and cause a valve malfunction.
Please check the pressure differential and flow to select 
THEAPPROPRIATESIZEOFTHEVALVEREFERRINGTOTHE&LOWRATE
Characteristics on page 34. Ensure that pressure 
differential does not become lower than 0.01 MPa during 
ON (N.C.: Valve open).
1. Cannot be used as an emergency shutoff valve etc.
The valves presented in this catalogue are not designed for 
safety applications such as an emergency shutoff valve. If the 
valves are used in this type of system, other reliable safety 
assurance measures should also be adopted.
%XTENDEDPERIODSOFCONTINUOUSENERGIZATION
The solenoid coil will generate heat when continuously 
energized. Avoid using in a tightly shut container. Install it in a 
well ventilated area. Furthermore, do not touch it while it is 
being energized or right after it is energized.
3. Liquid rings
In cases with a flowing liquid, provide a bypass valve in the 
system to prevent the liquid from entering the liquid seal circuit.
4. Actuator drive
When an actuator, such as a cylinder, is to be driven using a 
valve, take appropriate measures to prevent potential danger 
caused by actuator operation.
5. Pressure (including vacuum) holding
It is not usable for an application such as holding the pressure 
(including vacuum) inside of a pressure vessel because air 
leakage is entailed in a valve.
6. When the conduit type is used as equivalent to an 
IP65 enclosure, install a wiring conduit etc.
7. When an impact, such as water hammer etc., 
caused by the rapid pressure fluctuation is applied, 
the solenoid valve may be damaged. Give an 
attention to it.
2. Fluid
1) Type of fluid
Select an appropriate valve with reference to the table below 
for the general fluid. Before using a fluid, check whether it is 
compatible with the materials of each model by referring to 
the fluids listed in this catalogue. Use a fluid with a kinematic 
viscosity of 50 mm
2
/s or less. 
If there is something you do not know, please contact SMC.
2) Flammable oil, Gas
"Confirm the specification for leakage in the interior and/or 
exterior area."
3) Corrosive gas
Cannot be used since it will lead to cracks by stress 
corrosion or result in other incidents.
4) When a brass body is used, then depending on water 
quality, corrosion and internal leakage may occur. If such 
abnormalities occur, exchange the product for a stainless 
steel body.
5) Use an oil-free specification when any oily particle must not 
enter the passage.
6) Applicable fluid on the list may not be used depending on 
the operating condition. Give adequate confirmation, and 
then determine a model, just because the compatibility list 
shows the general case.
3. Air quality
<Air>
1) Use clean air.
Do not use compressed air that contains chemicals, 
synthetic oils including organic solvents, salt or corrosive 
gases, etc., as it can cause damage or malfunction.
2) Install an air filter.
Install air filters close to valves at their upstream side. 
filtration degree of 5 μm or less should be selected.
3) Install an aftercooler or air dryer, etc.
Compressed air that contains excessive drainage may 
cause malfunction of valves and other pneumatic equipment. 
To prevent this, install an aftercooler or air dryer, etc.
4) If excessive carbon powder is generated, eliminate it 
by installing mist separators at the upstream side of 
valves.
If excessive carbon powder is generated by the compressor, 
it may adhere to the inside of the valves and cause a 
malfunction.