Datasheet

Option
symbol
-
A
Seal material
Body material
Guide pin
material
Main valve
poppet
NBR
Fixed
sealant
NBR
FKM FKM
Brass (C37)
PPS
Coil
insulatio
n
type
B
Table (2) Solenoid Valve Option
∗ Aluminum is the only available material for the manifold base.
Note) The orifice diameter shows the supply pressure side/vacuum side.
How to Order Manifold Assemblies (Example)
How to Order Manifold Bases
Seal material
-
F
NBR
FKM
Blanking plate part no.
For VXV31:
VVX31-4A-
For VXV32/33: VVX32-4A-
Enter the valve and blanking plate to be mounted under the
manifold base part number.
Example
VVX311-05-1 ........ 1 set
∗
VXV3131-00-1GR1.. 4 sets
∗
VVX31-4A ........... 1 set
“
∗
” is the symbol for mounting.
Add an “
∗
” in front of the part numbers
for solenoid valves, etc. to be mounted.
VVX32
VVX31
VVX33
Manifold base
Number of
manifolds
02
•
•
•
10
2 stations
•
•
•
10 stations
11 07
Table (1) Port/Orifice Size
—
—
Solenoid
valve
Orifice symbol (diameter)
Note)
VXV31
VXV32
VXV33
3
(1.5/3 mmø)
—
4
(2.2/4 mmø)
1
2
Rc1/8
Rc1/4
Type
N.C.
N.O.
1
3
3
1
∗ Common port sizes are all Rc1/4.
∗ Indicating numbers shown below are for common ports.
Port size (Individual port)
22
Series VVXV31/32/33
Vacuum side port SUP side port
Table (3) Rated Voltage – Electrical Option
AC/
DC
AC
DC
Rated voltage
Voltage
symbol
1
2
3
4
7
8
J
5
6
100 V
200
V
110
V
220
V
240
V
48
V
230
V
24 V
12
V
Voltage
With surge
voltage
suppressor
S
—
Class B
With
light
L
—
—
—
—
With light and
surge voltage
suppressor
Z
—
—
∗ Class H coil is not available.
Note 1) Option S, Z are not available as a surge voltage suppresor is integrated
into the AC/Class B coil as standard.
Note 1) Note 1)
For Vacuum Pad/Manifold
How to Order (Solenoid Valve for Manifold)
U side
1
2
3
4
5
n
Station
D side
Enter the product’s part
number in order, counting
from
the 1st station on
the left in the manifold
arrangement, when vie-
wed with the individual
ports in front
.
The common ports on the
right side are plugged.
Valve/Body configuration
1
3
N.C. / Manifold
N.O. / Manifold
VXV
3 1 1
31 G
VXV
3 1 5 1
31 G
Model
Refer to Table (1) shown
below for availability.
Orifice size
Refer to Table (1) shown
below for availability.
Solenoid valve option
Refer to Table (2) shown
below for availability.
Rated voltage
1
2
3
4
5
100 VAC 50/60 Hz
200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
24 VDC
6
7
8
J
12 VDC
240 VAC 50/60 Hz
48 VAC 50/60 Hz
230 VAC 50/60 Hz
∗ Refer to Table (3) shown below for availability.
Refer to page 3 for ordering coil only.
Suffix
00
00
R1
With full-wave rectifier,
surge voltage suppressor
Electrical entry (AC/DC)
∗ Refer to Table (3) for the available combinations between each electrical
option (S, L, Z) and rated voltage.
∗ Surge voltage suppressor is integrated into the AC/Class B coil as standard.
G -
Grommet
GS-
With grommet
surge voltage
suppressor
C-
Conduit
T -
With conduit terminal
TS -
With conduit terminal and surge
voltage suppressor
TL -
With conduit terminal and light
TZ -
With conduit terminal, surge
voltage suppressor
and light
D -
DIN
DS -
DIN with surge voltage
suppressor
DL -
DIN with light
DZ -
DIN with surge voltage
suppressor and light
DO -
For DIN (without
connector
)
∗ DIN type is available with class B
insulation only.
DC
DC
AC/Class B coil (with
full-wave rectifier)
-
Z
—
Oil free