Datasheet

20
Series VXV31/32/33
For Vacuum Pad/Single Unit
How to Order (Single Unit)
Valve/Body configuration
0
2
N.C. / Single unit
N.O. / Single unit
Port size
Refer to Table (1) shown below for availability.
Thread type
-
T
F
N
Rc
NPTF
G
NPT
0
01
Solenoid valve option
Refer to Table (2) shown
below for availability.
Suffix
Rated voltage
1
2
3
4
5
100 VAC 50/60 Hz
200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
24 VDC
6
7
8
J
12 VDC
240 VAC 50/60 Hz
48 VAC 50/60 Hz
230 VAC 50/60 Hz
∗ Refer to Table (3) shown below for availability.
Refer to page 3 for ordering coil only.
Bracket
-
B
None
With bracket
∗ Bracket is not
removable.
G1
DC
0
01
1
G5
Electrical entry (AC/DC)
G -
Grommet
GS-
With grommet surge
voltage suppressor
C-
Conduit
T -
With conduit terminal
TS -
With conduit terminal and
surge voltage suppressor
TL -
With conduit terminal
and light
TZ -
With conduit
terminal, surge
voltage suppressor
and light
D -
DIN
DS -
DIN with surge voltage
suppressor
DL -
DIN with light
DZ -
DIN with surge
voltage suppressor
and light
DO -
For
DIN
(without connector)
∗ DIN type is available with class B insulation only.
Table (1) Port/Orifice Size
Table (2) Solenoid Valve Option
Solenoid valve
VXV31
Model
VXV32 VXV33
Port no.
(Port size)
—
—
—
—
—
—
Orifice symbol (diameter)
Note)
3
(1.5/3 mmø)
4
(2.2/4 mmø)
—
—
—
—
02
( )
03
( )
02
( )
03
( )
01
( )
02
( )
Note) The orifice diameter shown above are for the supply pressure side/
vacuum side port.
Option
symbol
-
A
G
H
Seal material
Body material
Guide pin
material
Main valve
poppet
NBR
FKM
NBR
FKM
Fixed
seals
NBR
FKM
NBR
FKM
Brass (C37)
Stainless steel
PPS
Coil
insulation
type
B
∗ Refer to Table (3) for the available combinations between each electrical
option (S, L, Z) and rated voltage.
∗ Surge voltage suppressor is integrated into the AC/Class B coil as standard.
Table (3) Rated Voltage – Electrical Option
AC/
DC
AC
DC
Rated voltage
Voltage
symbol
1
2
3
4
7
8
J
5
6
100
V
200
V
110
V
220
V
240 V
48
V
230
V
24
V
12
V
Voltage
With surge
voltage
suppressor
S
—
Class B
With
light
L
—
—
—
—
With light and
surge voltage
suppressor
Z
—
—
Note 1) Note 1)
Note 1) Option S, Z are not available as a surge voltage
suppresor is integrated into the AC/Class B
coil as standard.
∗ Class H coil is not available.
VXV
3
31
Model
Refer to Table (1) shown
below for availability.
VXV
331
Orifice size
Refer to Table (1) shown
below for availability.
R1
With full-wave rectifier,
surge voltage
suppressor
DC
AC/Class B coil (with
full-wave rectifier)
Connector
1
4
3
8
1
4
3
8
1
8
1
4
-
Z
—
Oil free