Datasheet

19
Series VXV31/32/33
For Vacuum Pad
Vacuum circuit side is suited for a large orifice. Supply pressure side is suited for high pressure
and a vacuum pad.
Construction and dimensions are the same as the VX3 series.
Passage symbol (example)Passage symbol (example)
Model/Valve Specifications
N.C.
N.O.
Power source
AC (Class B), DC
Ambient
temperature
(°C)
–20 to 60
Operating fluid
temperature (°C)
–10
Note 1)
to 60
Note 1) Dew point temperature: –10°C or less
Note) Value when air pressure is applied.
NBR, FKM
Air
1 cm
3
/min or less
Seal material
Leakage rate
Note)
Port size
Model
Orifice size (mmø)
b
Cv
Flow characteristics
Weight
(g)
3
1.5
3
1.5
4
2.2
4
2.2
VXV3130-01
VXV3132-01
VXV3130-02
VXV3132-02
VXV3240-02
VXV3340-02
VXV3242-02
VXV3342-02
VXV3240-03
VXV3340-03
VXV3242-03
VXV3342-03
0.20
0.32
0.20
0.32
0.20
0.40
0.20
0.40
C[dm
3
/
(s·bar)]
Port 3 sidePort 1 sidePort 1 side
1.5
3
1.5
3
2.2
4
2.2
4
Port 3 side
0.82
0.29
0.82
0.29
1.6
0.64
1.6
0.64
0.20
0.08
0.20
0.08
0.38
0.17
0.38
0.17
Max.
system
pressure
(MPa)
2.0
380
1
8
(6A)
1
4
(8A)
3
8
(10A)
0.29
0.82
0.29
0.82
0.64
1.6
0.64
1.6
C[dm
3
/
(s·bar)]
0.08
0.20
0.08
0.20
0.17
0.38
0.17
0.38
Cv
0.32
0.20
0.32
0.20
0.40
0.20
0.40
0.20
b
Passage: 1 2
Passage: 2 3
530
730
530
730
530
730
530
730
Operating pressure
(MPa)
0 to 0.5
Medium vacuum
0 to 0.5
Medium vacuum
0 to 0.5
0 to 0.9
0 to 0.5
0 to 0.9
Medium vacuum
0 to 0.5
Medium vacuum
0 to 0.5
0 to 0.5
0 to 0.9
0 to 0.5
0 to 0.9
Medium
vacuum
Medium
vacuum
Medium
vacuum
Medium
vacuum
Note) Weight of grommet type. Add 10 g for conduit, 30 g for DIN terminal, and 60 g for terminal type respectively.
Also, add 60 g for VX31
, 80 g for VX32 and VX33 respectively for bracket option.
• Refer to “Glossary of Terms” on front matter 9, for details on the max. operating pressure differential and the max. system pressure.
2
3
1
2
3
1
Note)
Operating Fluid and Ambient Temperature
Tightness of Valve (Leakage Rate)