Datasheet

15
Direct Operated 3 Port Solenoid Valve
Series VVX31/32/33
How to Order Manifold Assemblies (Example)
How to Order Manifold Bases
Seal material
-
F
NBR
FKM
Blanking plate part no.
For VX31:
VVX31-4A-
For VX32/33:
VVX32-4A-
Enter the valve and blanking plate to be mounted under the
manifold base part number.
Example
VVX311-05-1
.....
1 set
VX3111-00-1GR1 ... 4 sets
VVX31-4A ........... 1 set
” is the symbol for mounting.
Add an “
” in front of the part numbers
for solenoid valves, etc. to be mounted.
VVX32
VVX31
VVX33
Manifold base
Number of
manifolds
02
10
2 stations
10 stations
-
Z
Oil free
1071
Suffix
1
2
Rc1/8
Rc1/4
Type SUP port EXH port
N.C.
N.O.
1
3
3
1
Common port sizes are all Rc1/4.
Indicating numbers shown below are for common
Port size (Individual port)
For Air/Manifold
For WaterFor Steam For OilFor Air
How to Order (Solenoid Valve for Manifold)
U side
1
2
3
4
5
n
Station
D side
Enter the product’s part
number in order, counting
from
the 1st station on
the left in the manifold
arrangement, when vie-
wed with the individual
ports in front
.
The common ports on the
right side are plugged.
Suffix
Valve/Body configuration
1
3
5
N.C. / Manifold
N.O. / Manifold
COM. / Manifold
Main valve
poppet
Option
symbol
-
V
Aluminum is the only available material for the manifold base.
Note) The leakage amount (10
–6
Pa·m
3
/sec) for the “V” and “M” option are
values when the differential pressure is 0.1 MPa.
Seal material
Body
materia
l
Guide pi
n
materia
l
NBR
Non-leak (10
–6
Pa
·
m
3
/
sec), Medium vacuum
(0.1 Pa.abs)
Fixed
seal
s
NBR
FKM FKM
Brass
(C37)
PPS
Coil
insulatio
n
type
Note
Note)
B
Table (2) Solenoid Valve Option
VX
1 1
31 G
VX
1
1
1 5 1
31 G
Model
Refer to Table (1) shown
below for availability.
Orifice size
Refer to Table (1) shown
below for availability.
Solenoid valve option
Refer to Table (2) shown
below for availability.
Rated voltage
1
2
3
4
5
100 VAC 50/60 Hz
200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
24 VDC
6
7
8
J
12 VDC
240 VAC 50/60 Hz
48 VAC 50/60 Hz
230 VAC 50/60 Hz
Refer to Table (3) shown below for availability.
Refer to page 3 for ordering coil only.
Table (1) Port/Orifice Size
Solenoid
valve
Orifice symbol (diameter)
VX31
VX32
VX33
1
(1.5 mmø)
2
(2.2 mmø)
3
(3 mmø)
4
(4 mmø)
00
00
Table (3) Rated Voltage – Electrical Option
AC/
DC
AC
DC
Rated voltage
Voltage
symbol
1
2
3
4
7
8
J
5
6
100 V
200 V
110 V
220 V
240 V
48 V
230 V
24 V
12 V
Voltage
With surge
voltage
suppressor
S
Class B
With
light
L
With light and
surge voltage
suppressor
Z
Note 1) Note 1)
Class H coil is not available.
Note 1) Option S, Z are not available as a surge voltage suppresor is integrated
into the AC/Class B coil as standard.
R1
With full-wave rectifier,
surge voltage suppressor
Electrical entry (AC/DC)
G -
Grommet
GS-
With grommet
surge voltage
suppressor
C-
Conduit
T -
With conduit terminal
TS -
With conduit terminal and surge
voltage suppressor
TL -
With conduit terminal and light
TZ -
With conduit terminal, surge
voltage suppressor
and light
D -
DIN
DS -
DIN with surge voltage
suppressor
DL -
DIN with light
DZ -
DIN with surge voltage
suppressor and
light
DO -
For
DIN
(without
connector)
DIN type is available with class B insulation only.
Refer to Table (3) for the available combinations between each electrical
option (S, L, Z) and rated voltage.
Surge voltage suppressor is integrated into the AC/Class B coil as standard.
DC
AC/Class B coil (with
full-wave rectifier)
-
Z
Oil free