Valve/Body configuration
0
2
4
N.C. / Single unit
N.O. / Single unit
COM. / Single unit
5
Direct Operated 3 Port Solenoid Valve
Series VX31/32/33
1 1
How to Order (Single Unit)
01 G
1 R1
01 G
VX
DC, AC/Class H coil
1 4
31
VX
AC/Class B coil (with
full-wave rectifier)
1 4
31
Model
Refer to Table (1) shown
below for availability.
Orifice size
Refer to Table (1) shown
below for availability.
Solenoid valve option
Refer to Table (2) shown
below for availability.
Port size
Refer to Table (1) shown below for availability.
Thread type
-
T
F
N
Rc
NPTF
G
NPT
Rated voltage
1
2
3
4
5
100 VAC 50/60 Hz
200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
24 VDC
6
7
8
J
12 VDC
240 VAC 50/60 Hz
48 VAC 50/60 Hz
230 VAC 50/60 Hz
∗ Refer to Table (3) shown below for availability.
Refer to page 3 for ordering coil only.
Bracket
-
B
None
With bracket
∗ Bracket is not
removable.
Suffix
-
Z
—
Oil free
Electrical entry
∗ Refer to Table (3) for the available combinations between each electrical option
(S, L, Z) and rated voltage.
∗ Surge voltage suppressor is integrated into the AC/Class B coil as standard.
G -
Grommet
GS-
With grommet surge
voltage suppressor
C-
Conduit
T -
With conduit terminal
TS -
With conduit terminal and
surge voltage suppressor
TL -
With conduit terminal
and light
TZ -
With conduit
terminal, surge
voltage suppressor
and light
D -
DIN
DS -
DIN with surge voltage
suppressor
DL -
DIN with light
DZ -
DIN with surge
voltage suppressor
and light
DO -
For
DIN
(without connector)
Connector
∗ DIN type is available with class B insulation only.
Table (1) Port/Orifice Size
Option
symbol
-
G
E
P
H
Seal material
Body material/
Shading coil
material
Note
Guide pin
material
Main valve
poppet
NBR
EPDM
FKM
Fixed
seals
NBR
EPDM
FKM
Brass (C37)
Stainless steel
Brass (C37)/Copper
Stainless steel/Silver
Stainless steel
PPS
Stainless
steel
PPS
Coil
insulation
type
B
H
B —
—
Heated water
Table (3) Rated Voltage – Electrical Option
Table (2) Solenoid Valve Option
AC/
DC
AC
DC
Rated voltage
Voltage
symbol
1
2
3
4
7
8
J
5
6
100
V
200
V
110
V
220
V
240
V
48
V
230
V
24
V
12
V
Voltage
With surge
voltage
suppressor
S
—
Note 1) Note 1)
Class B
With
light
L
—
—
—
—
With light and
surge voltage
suppressor
Z
—
—
DC specification is not
available.
AC/
DC
AC
DC
Rated voltage
Voltage
symbol
1
2
3
4
7
8
J
5
6
100
V
200 V
110
V
220
V
240
V
48
V
230
V
24
V
12
V
Voltage
With surge
voltage
suppressor
S
Class H
With
light
L
—
—
—
With light and
surge voltage
suppressor
Z
—
—
—
Solenoid valve
VX31
Model
VX32 VX33
Port no.
(Port size)
—
—
—
—
—
—
Orifice symbol (diameter)
1
(1.5 mmø)
2
(2.2 mmø)
3
(3 mmø)
4
(4 mmø)
—
—
—
—
02
( )
03
( )
02
( )
03
( )
01
( )
02
( )
1
4
3
8
1
4
3
8
1
8
1
4
Note 1)
Option S, Z are not available as a surge voltage
suppresor is integrated into the AC/Class B
coil as standard.
With full-wave rectifier,
surge voltage suppressor
For Water/Single Unit