Datasheet

Direct Operated 3 Port Solenoid Valve
Series VX31/32/33
3
For Water, Oil, Steam, Air
How to Order Solenoid Coil Assembly
1
5
G
N
1
2
3
Series
Electrical entry
VX31
VX32
VX33
5
6
Rated voltage
Note 1)
24 VDC
12 VDC
VX02
Note 1) Refer to Table (1) for the
available combinations.
AC/Class B coil (with full-wave rectifier)DC Coil
1
1
G
N R
1
2
3
Series
Electrical entry
VX31
VX32
VX33
1
2
3
4
7
8
J
Rated voltage
Note 1)
100 VAC 50/60 Hz
200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
240 VAC 50/60 Hz
48 VAC 50/60 Hz
230 VAC 50/60 Hz
VX02
Note 1) Refer to Table (1) for the
available combinations.
∗ Refer to Table (1) for the available combinations between each electrical
option and rated voltage.
G -
Grommet
GS-
With grommet surge
voltage suppressor
C-
Conduit
T -
With conduit terminal
TS -
With conduit terminal and
surge voltage suppressor
TL -
With conduit
terminal and
light
TZ -
With conduit
terminal, surge
voltage suppressor
and light
D -
DIN
DS -
DIN with surge
voltage suppressor
DL -
DIN with light
DZ -
DIN with surge
voltage suppressor
suppressor and light
DO -
For
DIN
(without
connector)
Connector
∗ Refer to Table (1) for the available combinations between each electrical
option and rated voltage.
∗ Surge voltage suppressor is integrated into the AC/Class B coil as standard.
G-
Grommet
C-
Conduit
T -
With conduit terminal
TL -
With conduit terminal
and light
D -
DIN
DL -
DIN with light
DO -
For
DIN
(without
connector)
Connector
AC/Class H coil
1
1
GN H
1
2
3
Series
Electrical entry
VX31
VX32
VX33
1
2
3
4
7
8
J
Rated voltage
Note 1)
100 VAC 50/60 Hz
200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
240 VAC 50/60 Hz
48 VAC 50/60 Hz
230 VAC 50/60 Hz
VX02
Note 1) Refer to Table (1) for the
available combinations.
∗ Refer to Table (1) for the available combinations between each electrical
option and rated voltage.
G -
Grommet
GS-
With grommet surge
voltage suppressor
C-
Conduit
T -
With conduit terminal
TS -
With conduit terminal and surge voltage suppressor
TL -
With conduit terminal and light
TZ -
With conduit terminal, surge
voltage suppressor
and
light
Z
Name plate part no.
Clip part no.
AZ-T-VX
Valve model
For VX31:
VX021N-10
For VX32:
VX022N-10
For VX33:
VX023N-10
Clip
Name plate
Solenoid coil
Table (1) Rated Voltage – Electrical Option
AC/
DC
AC
DC
Rated voltage
Voltage
symbol
1
2
3
4
7
8
J
5
6
100 V
200
V
110
V
220
V
240
V
48
V
230
V
24
V
12
V
Voltage
With surge
voltage
suppressor
S
—
Class B Class H
DC specification is not
available.
With
light
L
—
—
—
—
With light
and surge
voltage
suppressor
Z
—
—
With surge
voltage
suppressor
S
With
light
L
—
—
—
With light
and surge
voltage
suppressor
Z
—
—
—
Note 1) Option S, Z are not available as a surge voltage suppresor is
integrated into the AC/Class B coil as standard.
∗ When changing coils, AC/DC are not interchangeable with each other, and
Class B and H coils are also not interchangeable with each other.
Note 1) Note 1)
Enter by referring to
“How to Order”.