Datasheet
Standard Specifications
Valve
specifications
Coil
specifications
Valve construction
Withstand pressure
Body material
Seal material
Note 2)
Enclosure
Environment
Rated voltage
Allowable voltage fluctuation
Allowable leakage
voltage
Coil insulation type
Direct operated poppet
2.0 MPa (Resin body type 1.5 MPa)
Aluminium, Resin, C37 (Brass), Stainless steel
NBR, FKM
Dust-tight, Water-jet-proof type (IP65)
Note 1)
Location without corrosive or explosive gases
24 VAC, 48 VAC, 100 VAC, 110 VAC, 200 VAC, 220 VAC, 230 VAC, 240 VAC
12 VDC, 24 VDC
±10% of rated voltage
10% or less of rated voltage
2% or less of rated voltage
Class B, Class H
AC
DC
Solenoid Coil Specifications
Size 1
Size 2
Size 3
Size
4.5
7
10.5
Power consumption [W]
Note 1)
50
55
65
Temperature rise [°C]
Note 2)
DC Specification
Note 1) Power consumption, Apparent power: The value at ambient
temperature of 20°C and when the rated voltage is applied.
(Variation: ±10%)
Note 2) The value at ambient temperature of 20°C and when the rated
voltage is applied. The value depends on the ambient environ-
ment. This is for reference.
Note 1) Power consumption, Apparent power: The value at ambient
temperature of 20°C and when the rated voltage is applied.
(Variation: ±10%)
Note 2) The value at ambient temperature of 20°C and when the rated
voltage is applied. The value depends on the ambient environ-
ment. This is for reference.
Note 1) Power consumption, Apparent power: The value at ambient
temperature of 20°C and when the rated voltage is applied.
(Variation: ±10%)
Note 2) There is no difference in the frequency and the inrush and
energized apparent power, since a rectifying circuit is used in the
AC.
Note 3) The value at ambient temperature of 20°C and when the rated
voltage is applied. The value depends on the ambient environ-
ment. This is for reference.
Note 1) Power consumption, Apparent power: The value at ambient
temperature of 20°C and when the rated voltage is applied.
(Variation: ±10%)
Note 2) There is no difference in the frequency and the inrush and
energized apparent power, since a rectifying circuit is used in the
AC.
Note 3) The value at ambient temperature of 20°C and when the rated
voltage is applied. The value depends on the ambient environ-
ment. This is for reference.
Size 1
Size 2
Size 3
Size
7
9.5
12
60
70
70
Apparent power [VA]
Note 1) 2)
Temperature rise
[°C]
Note 3)
Class B Class B
Size 1
Size 2
Size 3
Size
9
12
15
100
100
100
Apparent power [VA]
Note 1) 2)
Temperature rise
[°C]
Note 3)
Class H
Size 1
Size 2
Size 3
Size
9
12
15
100
100
100
Apparent power (VA)
Note 1) 2)
Temperature rise
[°C]
Note 3)
Class H
Size 1
Size 2
Size 3
Size
9
10
14
60
70
70
Apparent power [VA]
Note 1) 2)
Temperature rise
[°C]
Note 3)
AC Specification (Built-in Full-wave Rectifier Type)AC Specification (Built-in Full-wave Rectifier Type)
Normally Closed (N.C.)
Size 1
Size 2
Size 3
Size
7.5
8.5
12.5
Power consumption [W]
Note 1)
60
70
70
Temperature rise [°C]
Note 2)
DC Specification
Normally Open (N.O.)
Note 1) Electrical entry “Faston” type terminal is IP40.
Note 2) For seal material/EPDM, please contact SMC.
AC
DC
Be sure to read “Specific Product Precautions” before handling.
Series VX21/22/23
Common Specifications
Specifications
For Air
For Medium
Vacuum
For Water
For Oil
For Steam
Construction
Dimensions
3